UNLABELLED: Recent studies have reported high sensitivities for parathyroid localization with 99mTc-sestamibi and have been performed using either 123I/99mTc-sestamibi or a double-phase sestamibi scanning technique. These studies have focused primarily on patients undergoing initial surgery. We studied 35 patients prior to reoperative surgery to investigate the relative sensitivities of these two technique sin this patient population. METHODS: Double-phase sestamibi scanning (early and delayed imaging) was performed in all patients. Evaluable 123I/99mTc-sestamibi subtraction studies were also obtained in 25 patients. Results were correlated with surgical findings in 32 patients and with clinical outcome in 3 patients in whom mediastinal lesions were radiographically ablated. RESULTS: Overall, double-phase sestamibi imaging detected 23 of 39 abnormal parathyroid glands (59%), whereas 123I/99mTc-sestamibi detected 19 of 27 (70%). Oblique imaging, delayed imaging and 123I subtraction all contributed to sensitivity, and 123I subtraction also proved useful in patients with partial thyroid suppression. Two patients had lesions visible on the early sestamibi images that were not seen at all on the delayed scans. There were four false-positive findings. CONCLUSION: No significant differences between double-phase sestamibi and 123I/99mTc-sestamibi subtraction scanning were found, although the latter tended to be more sensitive.
UNLABELLED: Recent studies have reported high sensitivities for parathyroid localization with 99mTc-sestamibi and have been performed using either 123I/99mTc-sestamibi or a double-phase sestamibi scanning technique. These studies have focused primarily on patients undergoing initial surgery. We studied 35 patients prior to reoperative surgery to investigate the relative sensitivities of these two technique sin this patient population. METHODS: Double-phase sestamibi scanning (early and delayed imaging) was performed in all patients. Evaluable 123I/99mTc-sestamibi subtraction studies were also obtained in 25 patients. Results were correlated with surgical findings in 32 patients and with clinical outcome in 3 patients in whom mediastinal lesions were radiographically ablated. RESULTS: Overall, double-phase sestamibi imaging detected 23 of 39 abnormal parathyroid glands (59%), whereas 123I/99mTc-sestamibi detected 19 of 27 (70%). Oblique imaging, delayed imaging and 123I subtraction all contributed to sensitivity, and 123I subtraction also proved useful in patients with partial thyroid suppression. Two patients had lesions visible on the early sestamibi images that were not seen at all on the delayed scans. There were four false-positive findings. CONCLUSION: No significant differences between double-phase sestamibi and 123I/99mTc-sestamibi subtraction scanning were found, although the latter tended to be more sensitive.
Authors: Naris Nilubol; Lee Weinstein; William F Simonds; Robert T Jensen; Giao Q Phan; Marybeth S Hughes; Steven K Libutti; Stephen Marx; Electron Kebebew Journal: World J Surg Date: 2012-06 Impact factor: 3.352
Authors: Arnoldo Piccardo; P Trimboli; M Rutigliani; M Puntoni; L Foppiani; L Bacigalupo; Anna Crescenzi; G Bottoni; G Treglia; F Paparo; P Del Monte; M Lanata; G Paone; G Ferrarazzo; U Catrambone; A Arlandini; L Ceriani; M Cabria; L Giovanella Journal: Eur J Nucl Med Mol Imaging Date: 2018-09-15 Impact factor: 9.236
Authors: Anathea C Powell; H Richard Alexander; Richard Chang; Stephen J Marx; Monica Skarulis; James F Pingpank; David L Bartlett; Marybeth Hughes; Lee S Weinstein; William F Simonds; Michael F Collins; Thomas Shawker; Clara C Chen; James Reynolds; Craig Cochran; Seth M Steinberg; Steven K Libutti Journal: Surgery Date: 2009-12 Impact factor: 3.982
Authors: N Jaskowiak; J A Norton; H R Alexander; J L Doppman; T Shawker; M Skarulis; S Marx; A Spiegel; D L Fraker Journal: Ann Surg Date: 1996-09 Impact factor: 12.969
Authors: Janneke E Witteveen; Job Kievit; Marcel P M Stokkel; Hans Morreau; Johannes A Romijn; Neveen A T Hamdy Journal: World J Surg Date: 2011-01 Impact factor: 3.352
Authors: Anil Bhansali; Shariq Rashid Masoodi; K S Somashekara Reddy; Arunanshu Behera; Bishan das Radotra; Bhagwant Rai Mittal; Rabinder Nath Katariya; Radharaman Jiban Dash Journal: Ann Saudi Med Date: 2005 Jan-Feb Impact factor: 1.526