Literature DB >> 8522547

A theoretical solution for the frictionless rolling contact of cylindrical biphasic articular cartilage layers.

G A Ateshian1, H Wang.   

Abstract

Previous studies have shown that interstitial fluid pressurization plays an important role in the load support mechanism of articular cartilage under normal step loading. These studies have demonstrated that interstitial fluid pressurization decreases with time if the applied load is maintained constant. In the present study, a theoretical solution is obtained for another common loading of articular cartilage, namely the contact of surfaces in rolling motion. Pure rolling of symmetrical frictionless cylindrical cartilage layers is analyzed under steady state. The linear biphasic model of Mow et al. [J. Biomech. Engng 102, 73-84 (1980)] is used to describe the mechanical response of articular cartilage. The solution of this contact problem reduces to simultaneously solving a set of four integral equations, akin to the dual integral problem of elastic contact. It is found that the solution is dependent on four non-dimensional parameters: Rh = Vb/HAk, W/2 mu b, R/b, and v, where V is the surface velocity, b the cartilage thickness, HA the aggregate modulus, mu the shear modulus, v Poisson's ratio, k the permeability, R the radius of cylindrical surfaces, and W the applied load per unit cylinder length. For Rh << 1, interstitial fluid pressurization is found to be negligible, and all the applied load is supported by the solid collagen-proteoglycan phase of the tissue, thus causing significant cartilage deformation. As Rh increases to a physiological level (Rh approximately 10(4)), interstitial fluid pressurization may support more than 90% of the total applied load, shielding the solid matrix from high effective stresses and reducing matrix strains and deformation. The protective effect of interstitial fluid pressurization is observed to increase with increasing joint congruence (R/b); similarly, as the applied load (W/2 mu b) is increased, a greater proportion of it is supported by the fluid. In degenerative cartilage, Rh may drop by one or more orders of magnitude, primarily as a result of increased permeability. Thus, the protective stress-shielding effect of interstitial fluid pressurization may become less effective in diseased tissue, possibly setting a pathway for further tissue degeneration.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 8522547     DOI: 10.1016/0021-9290(95)00008-6

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  41 in total

1.  Biphasic finite element modeling of hydrated soft tissue contact using an augmented Lagrangian method.

Authors:  Hongqiang Guo; Robert L Spilker
Journal:  J Biomech Eng       Date:  2011-11       Impact factor: 2.097

2.  A Model to Study Articular Cartilage Mechanical and Biological Responses to Sliding Loads.

Authors:  Oliver R Schätti; Luigi M Gallo; Peter A Torzilli
Journal:  Ann Biomed Eng       Date:  2015-12-23       Impact factor: 3.934

3.  Fluid load support during localized indentation of cartilage with a spherical probe.

Authors:  E D Bonnevie; V J Baro; L Wang; D L Burris
Journal:  J Biomech       Date:  2012-01-28       Impact factor: 2.712

4.  A theoretical analysis of water transport through chondrocytes.

Authors:  G A Ateshian; K D Costa; C T Hung
Journal:  Biomech Model Mechanobiol       Date:  2006-05-17

5.  Analysis of radial variations in material properties and matrix composition of chondrocyte-seeded agarose hydrogel constructs.

Authors:  T-A N Kelly; K W Ng; G A Ateshian; C T Hung
Journal:  Osteoarthritis Cartilage       Date:  2008-09-19       Impact factor: 6.576

6.  The friction coefficient of shoulder joints remains remarkably low over 24 h of loading.

Authors:  Brian K Jones; Krista M Durney; Clark T Hung; Gerard A Ateshian
Journal:  J Biomech       Date:  2015-10-09       Impact factor: 2.712

Review 7.  Surgical management of labral tears during femoroacetabular impingement surgery: a systematic review.

Authors:  O R Ayeni; J Adamich; F Farrokhyar; N Simunovic; S Crouch; M J Philippon; M Bhandari
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-02-12       Impact factor: 4.342

8.  Microscale frictional response of bovine articular cartilage from atomic force microscopy.

Authors:  Seonghun Park; Kevin D Costa; Gerard A Ateshian
Journal:  J Biomech       Date:  2004-11       Impact factor: 2.712

9.  Finite element prediction of transchondral stress and strain in the human hip.

Authors:  Corinne R Henak; Gerard A Ateshian; Jeffrey A Weiss
Journal:  J Biomech Eng       Date:  2014-02       Impact factor: 2.097

10.  Scaffold-free cartilage subjected to frictional shear stress demonstrates damage by cracking and surface peeling.

Authors:  G Adam Whitney; Karthik Jayaraman; James E Dennis; Joseph M Mansour
Journal:  J Tissue Eng Regen Med       Date:  2014-06-26       Impact factor: 3.963

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.