Literature DB >> 8517387

Cine magnetic resonance imaging and color Doppler flow mapping in infants and children with pulmonary artery bands.

I A Simpson1, L M Valdes-Cruz, D P Berthoty, J B Powell, J R Hesselink, K J Chung, D J Sahn.   

Abstract

Cine magnetic resonance imaging (MRI) and color Doppler flow mapping were performed in 12 infants and children (aged 3 to 35 months) after pulmonary artery banding to define the anatomy and physiology of the right ventricular outflow tract and evaluate the anatomy. MRI was performed using a 1.5 Tesla magnet in the sagittal, axial and oblique views with all patients studied in the 24 cm head coli following adequate sedation. High-resolution cine MRI was obtained in all patients and the narrowest flow diameter on cine MRI correlated well with the pressure gradient measured across the band in 11 patients at cardiac catheterization or surgery (r = -0.95). Signal loss was always seen distal to the band associated with turbulent flow as seen by color Doppler flow mapping. Signal loss in cine MRI was also seen proximal to the band. The length of this proximal signal void also correlated well with the pressure gradient measured across the band (r = 0.91) and was closely matched by the zone of proximal spatial acceleration defined by digital computer analysis of color Doppler flow map images (r = 0.89), which also demonstrated low grade variance associated with the laminar accelerating flow stream. The position of the band was accurately defined by cine MRI which identified inadequate pulmonary artery banding in 2 patients confirmed subsequently at cardiac catheterization and angiography. Cine MRI and color Doppler flow mapping when used together provide high-resolution detail about the right ventricular outflow tract and pulmonary artery band anatomy and function.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1993        PMID: 8517387     DOI: 10.1016/0002-9149(93)90603-a

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  3 in total

Review 1.  Magnetic resonance imaging in congenital heart disease in children.

Authors:  A E Schlesinger; R J Hernandez
Journal:  Tex Heart Inst J       Date:  1996

2.  Fludrocortisone in the management of an infant with a single ventricle and an overly tightened pulmonary artery band.

Authors:  K M Ponciroli; S B Jureidini; D Dempsher; I Balfour
Journal:  Pediatr Cardiol       Date:  2006 Sep-Oct       Impact factor: 1.655

3.  Magnetic resonance imaging in paediatrics.

Authors:  G R Cherryman
Journal:  Arch Dis Child       Date:  1994-02       Impact factor: 3.791

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.