Heat loss during surgical skin preparation.

D I Sessler1, A M Sessler, S Hudson, A Moayeri.   

Abstract

BACKGROUND: Hypothermia develops rapidly during the 1st h of anesthesia and results in part from evaporative heat loss during surgical skin preparation. The authors tested the hypothesis that evaporation of skin preparation solution contributes significantly to hypothermia.
METHODS: Five healthy, unanesthetized volunteers were studied in a 22 +/- 0.4 degrees C environment. One thigh of each volunteer was washed for 10 min, using each of the following representative solutions: (1) water; (2) 50% ethanol in water (EtOH/H2O; similar to tincture of iodine); and (3) povidone-iodine gel. Water and EtOH/H2O each were tested at ambient temperature (cold), warmed to 40 degrees C before application (warm), and with radiant heating of the skin, and gel only at ambient temperatures, resulting in seven study states. Heat loss and skin temperatures on the washed thighs were measured using thermal flux transducers, and values compared with the data obtained from the contralateral unwashed thighs. Change in mean body temperature (per 70 kg) due to washing was calculated by integrating measured heat loss over time and multiplying by the specific heat of human tissue. A mathematical model was developed to predict cutaneous heat loss using only skin temperature, independent of the type and temperature of skin-preparation solution or the use of radiant heating during preparation.
RESULTS: Heat loss from the unwashed thigh was approximately 14 kcal/m2 during radiant warming and approximately 39 kcal/m2 without warming. Net heat loss (increment produced by washing) was approximately 30 kcal/m2 with water and gel without radiant warming, but loss was larger with EtOH/H2O than with water under all study conditions. Radiant warming reduced total heat loss (increment produced by washing and environment) during both the EtOH/H2O and water trials, compared with warm or cold EtOH/H2O and water alone. The calculated decreases in mean body temperature per 70 kg ranged from -0.2 to -0.7 degree C/m2. The smallest decrease occurred during radiant warming and washing with water, and the largest decreases during warm or cold EtOH/H2O.
CONCLUSIONS: Heat loss was significantly less with water-based than with alcohol-based solutions. Though heating the solutions and radiant warming decreased heat loss, such loss under each tested condition, even per square meter of washed surface, was small compared to other causes of perioperative hypothermia. Consequently, the authors recommend that efforts to maintain intraoperative normothermia be directed elsewhere.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8512098     DOI: 10.1097/00000542-199306000-00007

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  6 in total

1.  Comparison of the coaxial circle circuit with the conventional circle circuit.

Authors:  Ayse Mizrak; Murat Bilgi; Senem Koruk; Suleyman Ganidagli; Erkan Karatas; Unsal Oner; Rauf Gul; Levent Sahin
Journal:  Eurasian J Med       Date:  2011-08

2.  The influence of menthol on thermoregulation and perception during exercise in warm, humid conditions.

Authors:  D Jason Gillis; James R House; Michael J Tipton
Journal:  Eur J Appl Physiol       Date:  2010-06-24       Impact factor: 3.078

3.  Effects of a Heated Anesthesia Breathing Circuit on Body Temperature in Anesthetized Rhesus Macaques (Macaca mulatta).

Authors:  Philip A Bowling; Michael A Bencivenga; Mary E Leyva; Brittnee E Grego; Robin N Cornelius; Emily M Cornelius; Chase D Cover; Chase A Gonzales; David P Fetterer; Cara P Reiter
Journal:  J Am Assoc Lab Anim Sci       Date:  2021-10-27       Impact factor: 1.232

4.  Cutaneous heat loss with three surgical drapes, one impervious to moisture.

Authors:  Paul E Maglinger; Daniel I Sessler; Rainer Lenhardt
Journal:  Anesth Analg       Date:  2005-03       Impact factor: 6.627

5.  The use of a cold pack during resistance exercises is effective for reducing intramuscular oxygenation and increasing myoelectric activity.

Authors:  Masahiro Goto; Yoshihiro Yamashina; Akihiro Takada; Yui Kikuchi; Takafumi Hamaoka; Shigeru Terada
Journal:  J Phys Ther Sci       Date:  2022-04-08

6.  The effect of preheated versus room-temperature skin disinfection on bacterial colonization during pacemaker device implantation: a randomized controlled non-inferiority trial.

Authors:  Camilla Wistrand; Bo Söderquist; Anders Magnusson; Ulrica Nilsson
Journal:  Antimicrob Resist Infect Control       Date:  2015-11-03       Impact factor: 4.887

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.