Literature DB >> 851207

A solid-state arteriovenous oxygen difference analyzer for flowing whole blood.

A P Shepherd, C G Burgar.   

Abstract

This communication describes a spectrophotometric device which determines the arteriovenous oxygen difference (a-v O2) on whole blood flowing through optical cuvettes. The instrument consists entirely of commercially available solid-state components, including the light sources, light-emitting diodes. When calibrated against conventional determinations of blood oxygen content, the output of the a-v O2 analyzer was shown to be highly linear and to be independent of total hemoglobin concentration. The electronic circuit, the theory of the measurement, and sources of error are described in detail.

Entities:  

Mesh:

Substances:

Year:  1977        PMID: 851207     DOI: 10.1152/ajpheart.1977.232.4.H437

Source DB:  PubMed          Journal:  Am J Physiol        ISSN: 0002-9513


  18 in total

1.  Influence of ventricular contractility on non-work-related myocardial oxygen consumption.

Authors:  D Burkhoff; D T Yue; R Y Oikawa; M R Franz; J Schaefer; K Sagawa
Journal:  Heart Vessels       Date:  1987       Impact factor: 2.037

2.  The effect of catecholamines on intestinal glucose and oxygen uptake in the dog.

Authors:  J Grayson; D D Oyebola
Journal:  J Physiol       Date:  1983-10       Impact factor: 5.182

3.  Ejecting activation differs in energetics from ordinary positive inotropism in the canine left ventricle.

Authors:  Y Yasumura; T Nozawa; S Futaki; N Tanaka; H Suga
Journal:  Heart Vessels       Date:  1994       Impact factor: 2.037

4.  Insights into the effects of contraction dyssynchrony on global left ventricular mechano-energetic function.

Authors:  Lauren Johnson; Marc A Simon; Michael R Pinsky; Sanjeev G Shroff
Journal:  Pacing Clin Electrophysiol       Date:  2009-02       Impact factor: 1.976

5.  Gastrointestinal secretory, motor, circulatory, and metabolic effects of prosomatostatin.

Authors:  S J Konturek; J Tasler; J Jaworek; W Pawlik; K M Walus; V Schusdziarra; C A Meyers; D H Coy; A V Schally
Journal:  Proc Natl Acad Sci U S A       Date:  1981-03       Impact factor: 11.205

6.  Mesenteric vascular reactivity to histamine receptor agonists and antagonists.

Authors:  K M Walus; J D Fondacaro; E D Jacobson
Journal:  Dig Dis Sci       Date:  1981-05       Impact factor: 3.199

7.  A new cardiotonic agent, OPC-8212, elevates the myocardial oxygen consumption versus pressure-volume area (PVA) relation in a similar manner to catecholamines and calcium in canine hearts.

Authors:  S Futaki; T Nozawa; Y Yasumura; N Tanaka; H Suga
Journal:  Heart Vessels       Date:  1988       Impact factor: 2.037

8.  Force-time integral does not improve predictability of cardiac O2 consumption from pressure-volume area (PVA) in dog left ventricle.

Authors:  H Suga; T Nozawa; Y Yasumura; S Futaki; Y Ohgoshi; H Yaku; Y Goto
Journal:  Heart Vessels       Date:  1990       Impact factor: 2.037

9.  Oxygen and coronary vascular resistance during autoregulation and metabolic vasodilation in the dog.

Authors:  A J Drake-Holland; J D Laird; M I Noble; J A Spaan; I Vergroesen
Journal:  J Physiol       Date:  1984-03       Impact factor: 5.182

10.  Contractility to minimize oxygen consumption for constant work in dog left ventricle.

Authors:  N Tanaka; T Nozawa; Y Yasumura; S Futaki; K Hiramoi; H Suga
Journal:  Heart Vessels       Date:  1990       Impact factor: 2.037

View more