Literature DB >> 851059

Echocardiographic evaluation of septal motion in patients with artificial pacemakers: vectorcardiographic correlations.

S Zoneraich, O Zoneraich, J J Rhee.   

Abstract

Twenty-one patients with transvenous endocardial right ventricular pacemakers and one patient with epicardial right ventricular pacemaker inducing artificial left bundle branch block (LBBB) were studied with echocardiographic and vectorcardiographic techniques. Sixteen patients were found to have an initial very active posterior motion of the interventricular septum occurring within 70 msec. (range, 40 to 100 msec.) of the pacemaker artefact followed by posterior movement during the ejection period (Pattern A). Eighteen of 20 patients with clinical LBBB serving as a control group showed a dynamic posterior motion occurring within 40 msec. of the onset of QRS and preceding anterior (paradoxical) motion of the septum during ejection. In four patients, following the initial brief posterior septal movement, there was flat or anterior movement of the septum during the ejection period (Patern B). Two patients had myocardial infarction and one had atrial septal defect and epicardial right ventricular pacemaker. Only in two patients the initial brief posterior septal motion was not recorded before moving posteriorly during the ejection period (Pattern C). The different patterns of septal motion found in patients with artificial LBBB and in those with natural LBBB could be explained by differences in activation of the heart, as shown by vectorcardiography. Echocardiographic septal evaluation of patients with artificial pacemakers could have diagnostic implications in suggesting possible underlying complicating cardiac abnormalities.

Entities:  

Mesh:

Year:  1977        PMID: 851059     DOI: 10.1016/s0002-8703(77)80010-0

Source DB:  PubMed          Journal:  Am Heart J        ISSN: 0002-8703            Impact factor:   4.749


  7 in total

1.  Transient abnormal septal motion after non-surgical closure of the ductus arteriosus.

Authors:  S Beppu; Y Masuda; H Sakakibara; S Izumi; Y D Park; S Nagata; K Miyatake; Y Nimura
Journal:  Br Heart J       Date:  1988-06

2.  M-mode and cross-sectional echocardiographic study of the left ventricular wall motions in complete left bundle-branch block.

Authors:  J Fujii; H Wantanabe; T Watanabe; N Takahashi; A Ohta; K Kato
Journal:  Br Heart J       Date:  1979-09

Review 3.  Selection and optimisation of biventricular pacing: the role of echocardiography.

Authors:  R E Lane; A W C Chow; D Chin; J Mayet
Journal:  Heart       Date:  2004-12       Impact factor: 5.994

4.  Differing effects of right ventricular pacing and left bundle branch block on left ventricular function.

Authors:  H B Xiao; S J Brecker; D G Gibson
Journal:  Br Heart J       Date:  1993-02

5.  Role of coronary flow regulation and cardiac-coronary coupling in mechanical dyssynchrony associated with right ventricular pacing.

Authors:  Lei Fan; Ravi Namani; Jenny S Choy; Yousif Awakeem; Ghassan S Kassab; Lik Chuan Lee
Journal:  Am J Physiol Heart Circ Physiol       Date:  2020-12-24       Impact factor: 4.733

6.  Incidence and fate of the abnormal septal motion after open heart surgeries.

Authors:  Jae-Hyeong Park
Journal:  J Cardiovasc Ultrasound       Date:  2014-03-31

7.  Echocardiographic investigation of the mechanism underlying abnormal interventricular septal motion after open heart surgery.

Authors:  Min-Kyung Kang; Hyuk-Jae Chang; In Jeong Cho; Sanghoon Shin; Chi-Young Shim; Geu-Ru Hong; Kyung-Jong Yu; Byung-Chul Chang; Namsik Chung
Journal:  J Cardiovasc Ultrasound       Date:  2014-03-31
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.