Literature DB >> 8507326

Influence of finish-line geometry on the fit of crowns.

J Z Syu1, G Byrne, L W Laub, M F Land.   

Abstract

Previous studies on the fit of complete crowns have neglected to assess the internal adaptation of castings prior to cementation. Theoretical arguments and laboratory studies have failed to clarify which is the most desirable finish-line configuration in terms of marginal fit. This study evaluated axial and marginal fit of crowns made for three tooth preparations that had different labial finish-line configurations: shoulder, shoulder-bevel, and chamfer. The crowns were not cemented, but were sectioned and examined on their respective dies. There were no significant differences (P < or = .05) among groups for marginal or axial gaps. Crown fit was not influenced by any of the three finish lines tested, and castings with well-fitting margins exhibited measurable axial wall space.

Entities:  

Mesh:

Year:  1993        PMID: 8507326

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  6 in total

Review 1.  Tooth preparation for full-coverage restorations-a literature review.

Authors:  Anke Podhorsky; Peter Rehmann; Bernd Wöstmann
Journal:  Clin Oral Investig       Date:  2015-03-07       Impact factor: 3.573

2.  A tooth preparation technique in fixed prosthodontics for students and neophyte dentists.

Authors:  Daniele Rosella; Giancarlo Rosella; Edoardo Brauner; Piero Papi; Luca Piccoli; Giorgio Pompa
Journal:  Ann Stomatol (Roma)       Date:  2016-02-12

3.  Glass Ceramic CAD/CAM crowns and severely altered posterior teeth: a three levels study.

Authors:  Michel Fages; Stephane Corn; Pierre Slangen; Jacques Raynal; Patrick Ienny; Kinga Turzo; Frederic Cuisinier; Jean-Cédric Durand
Journal:  J Mater Sci Mater Med       Date:  2017-08-19       Impact factor: 3.896

4.  Comparative analysis of the clinical techniques used in evaluation of marginal accuracy of cast restoration using stereomicroscopy as gold standard.

Authors:  Abhishek Rastogi; Vikas Kamble
Journal:  J Adv Prosthodont       Date:  2011-06-30       Impact factor: 1.904

5.  Evaluation of marginal fit of two all-ceramic copings with two finish lines.

Authors:  Gulce Subasi; Nilgun Ozturk; Ozgur Inan; Nalan Bozogullari
Journal:  Eur J Dent       Date:  2012-04

6.  Comparison of the fit of cast gold crowns fabricated from the digital and the conventional impression techniques.

Authors:  Mi-Jung Yun; Young-Chan Jeon; Chang-Mo Jeong; Jung-Bo Huh
Journal:  J Adv Prosthodont       Date:  2017-02-07       Impact factor: 1.904

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.