Literature DB >> 8500332

Effects of BSS and BSS+ irrigation solutions on rabbit corneal transendothelial electrical potential difference.

J Li1, R Akiyama, K Kuang, J Fischbarg.   

Abstract

Measurements of electrical potential difference across isolated rabbit corneal endothelium (transendothelial electrical potential difference, TEPD) were used to evaluate the effect of two commonly used commercially prepared intraocular irrigation balanced salt solutions, BSS and BSS+, together with our own standard bicarbonate-containing control solution (BS). The highest and most durable TEPD values were obtained by using BSS+; TEPD began at 550 microV, peaked at 600 microV 1 h later, and then decreased slowly down to some 300 microV after about 8 h. Gassing BSS+ with an air/5% CO2 mixture was optimal; gassing it with air reduced the TEPD values slightly, by about 10%. On the other hand, perfusion with BSS gassed with air had a rapid and marked adverse effect; the TEPD, which began at some 500 microV, fell down precipitously to about 50 microV after 1 hour. In contrast, perfusion with BSS on the endothelial side with the addition of BS to the stromal side, both sides being gassed with an air/5% CO2 mixture, maintained the TEPD at levels near those obtained with BSS+. We attribute the adverse effect by BSS to the absence of bicarbonate in it. From these and past results, we conclude that BSS cannot be recommended for intraocular use as a properly balanced saline solution.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8500332     DOI: 10.1097/00003226-199305000-00003

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  3 in total

1.  Solutions containing miotic agents: effects on corneal transendothelial electrical potential difference.

Authors:  R Akiyama; K Kuang; J P Koniarek; P A Chiaradía; C W Roberts; J Fischbarg
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1997-06       Impact factor: 3.117

2.  Intraocular irrigating solutions: a comparison of Hartmann's lactated Ringer's solution, BSS and BSS Plus.

Authors:  R M Nuyts; H F Edelhauser; G P Holley
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1995-10       Impact factor: 3.117

3.  A new, specular reflection-based, precorneal tear film stability measurement technique in a rabbit model: viscoelastic increases tear film stability.

Authors:  Derek Nankivil; Alex Gonzalez; Esdras Arrieta; Cornelis Rowaan; Mariela C Aguilar; Krystal Sotolongo; Florence A Cabot; Sonia H Yoo; Jean-Marie A Parel
Journal:  Invest Ophthalmol Vis Sci       Date:  2014-06-19       Impact factor: 4.799

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.