Literature DB >> 8498755

Evaluation of skin viability in dogs, using transcutaneous carbon dioxide and sensor current monitoring.

M C Rochat1, J T Payne, E R Pope, C C Wagner-Mann, L W Pace.   

Abstract

Transcutaneous oxygen monitoring is commonly used in human beings to assess skin viability. Little attention has been directed toward the use of transcutaneous carbon dioxide (PCO2-TC) monitoring for the same purpose. The application of PCO2-TC monitoring for evaluating skin viability in dogs was investigated. The changes in PCO2-TC and local power reference (LPR) values were measured from 16 skin flaps created along the lateral hemithoraces of 4 dogs. Transcutaneous PCO2 and LPR values were serially recorded from the base and apex of each flap for 12 hours. A single measurement was obtained from each flap base and apex 24 hours after surgery. Arterial blood gas analyses were obtained to compare central PCO2 values with peripheral skin PCO2 values. The flaps were observed for 4 days and then harvested for histologic examination. Full-thickness skin biopsy specimens were obtained 24 hours after surgery and when the flaps were harvested to evaluate the viability of the apex and base of the flaps. A subjective grade was assigned to all skin biopsy specimens during histologic examination. For all measurements, a significant difference was found between the PCO2-TC values for apices and bases of the flaps. The mean PCO2-TC for all bases was 52.66 mm of Hg +/- 2.24 (SEM), and the mean PCO2-TC for all apices was 106.4 mm of Hg +/- 2.44. The regional carbon dioxide index (apex PCO2-TC/base PCO2-TC) was 2.02. A significant difference was not found between the LPR values for bases and apices.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8498755

Source DB:  PubMed          Journal:  Am J Vet Res        ISSN: 0002-9645            Impact factor:   1.156


  3 in total

Review 1.  Flap Monitoring Using Transcutaneous Oxygen or Carbon Dioxide Measurements.

Authors:  Sameer H Halani; Austin S Hembd; Xingchen Li; Ben Kirby; Courtney C Beard; Nicholas T Haddock; Thomas M Suszynski
Journal:  J Hand Microsurg       Date:  2020-11-16

2.  Transcutaneous CO2 Pressure Monitoring Increases Salvage Rates after Free Tissue Transplantation for Extremity Reconstruction.

Authors:  Takahiko Nakano; Toshiya Kudo; Yoshitomo Sano; Hiroaki Minehara; Masao Suzuki; Kohei Aoki; Takashi Matsushita
Journal:  Plast Reconstr Surg Glob Open       Date:  2022-08-19

3.  Transcutaneous PCO2 Measurement at Low Temperature for Reliable and Continuous Free Flap Monitoring: Experimental and Clinical Study.

Authors:  Yoshiro Abe; Ichiro Hashimoto; Keiichi Goishi; Keisuke Kashiwagi; Masahiro Yamano; Hideki Nakanishi
Journal:  Plast Reconstr Surg Glob Open       Date:  2013-06-07
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.