Literature DB >> 8498231

Diagnosis of carotid artery disease: preliminary experience with maximum-intensity-projection spiral CT angiography.

M P Marks1, S Napel, J E Jordan, D R Enzmann.   

Abstract

OBJECTIVE: Spiral CT allows continuous data to be acquired rapidly, and if a correctly timed IV bolus of contrast material is given, spiral CT angiography can be performed. This study was designed to evaluate spiral CT angiography with maximum-intensity-projection reconstructions for assessing the degree of carotid artery stenosis. SUBJECTS AND METHODS: Spiral CT angiography (of 28 carotid bifurcations in 14 patients) was compared in a blinded fashion with conventional angiography (of 28 bifurcations) and with two-dimensional time-of-flight MR angiography (of 12 bifurcations) to assess degree of stenosis. A nonblinded comparison of the contour of the lumen at the site of stenosis was then made between conventional angiography, spiral CT angiography, and MR angiography. The degree of stenosis was measured in each internal carotid artery and categorized as mild (< 30%), moderate (30-69%), or severe (70-99%) stenosis or as occlusion. Maximum-intensity-projection images were used for the evaluations; however, if calcification was circumferential and the lumen of the carotid artery could not be analyzed in the area of the calcification, the axial source images were used.
RESULTS: The results of CT angiography and conventional angiography agreed overall in 25 (89%) of 28 cases (r = .921, p = .05, Spearman rank correlation). The presence of severe stenosis or occlusion was correctly identified in seven of seven cases. In the moderate and mild stenosis categories, 18 (86%) of 21 were correctly identified (r = .802, p = .122). Three internal carotid arteries (11%) had circumferential calcification that necessitated evaluation of the axial source images, and the measurements obtained from the axial images agreed well with angiographic findings. MR angiography correlated well with the various categories of stenosis. However, when we compared MR angiography directly with CT angiography and conventional angiography, we found that the degree of stenosis was overestimated when MR angiography was used.
CONCLUSION: Our results show that spiral CT angiography shows normal and abnormal carotid anatomy well when compared with conventional angiography. The short examination time and clear depiction of arterial caliber in areas of stenosis are significant advantages of spiral CT angiography compared with MR angiography.

Entities:  

Mesh:

Year:  1993        PMID: 8498231     DOI: 10.2214/ajr.160.6.8498231

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  19 in total

1.  Prospective evaluation of carotid artery stenosis: elliptic centric contrast-enhanced MR angiography and spiral CT angiography compared with digital subtraction angiography.

Authors:  Juan Alvarez-Linera; Julián Benito-León; José Escribano; Jorge Campollo; Ricardo Gesto
Journal:  AJNR Am J Neuroradiol       Date:  2003-05       Impact factor: 3.825

2.  Total occlusion versus hairline residual lumen of the internal carotid arteries: accuracy of single section helical CT angiography.

Authors:  Michael H Lev; Javier M Romero; Daniel N F Goodman; Ranjit Bagga; H Young Kwon Kim; Neil A Clerk; Robert H Ackerman; R Gilberto Gonzalez
Journal:  AJNR Am J Neuroradiol       Date:  2003 Jun-Jul       Impact factor: 3.825

3.  Assessment of accuracy of renal artery stenosis grading in helical CT angiography using maximum intensity projections.

Authors:  L Van Hoe; D Vandermeulen; S Gryspeerdt; L Mertens; A L Baert; P Suetens; G Marchal; L Stockx
Journal:  Eur Radiol       Date:  1996       Impact factor: 5.315

4.  Multi-detector row CT angiography in the assessment of carotid artery disease in symptomatic patients: comparison with rotational angiography and digital subtraction angiography.

Authors:  Marja Berg; Zishu Zhang; Aki Ikonen; Petri Sipola; Reetta Kälviäinen; Hannu Manninen; Ritva Vanninen
Journal:  AJNR Am J Neuroradiol       Date:  2005-05       Impact factor: 3.825

5.  Semi-automated computer assessment of the degree of carotid artery stenosis compares favorably to visual evaluation.

Authors:  Max Wintermark; Christine Glastonbury; Elizabeth Tong; Benison C Lau; Sarah Schaeffer; Jeffrey D Chien; Peter J Haar; David Saloner
Journal:  J Neurol Sci       Date:  2008-01-29       Impact factor: 3.181

6.  Grading of carotid artery stenosis in the presence of extensive calcifications: dual-energy CT angiography in comparison with contrast-enhanced MR angiography.

Authors:  A Korn; B Bender; H Brodoefel; T-K Hauser; S Danz; U Ernemann; C Thomas
Journal:  Clin Neuroradiol       Date:  2013-12-17       Impact factor: 3.649

7.  Three-dimensional reconstructions of carotid bifurcation from CT images: evaluation of different rendering methods.

Authors:  Z Tarjàn; F Pozzi Mucelli; F Frezza; R Pozzi Mucelli
Journal:  Eur Radiol       Date:  1996       Impact factor: 5.315

8.  A method for improving iodine contrast enhancement in abdominal computed tomography: experimental study in a pig model.

Authors:  Peter B Noël; Edgar Bendik; Daniela Münzel; Armin Schneider; Liran Goshen; Asher Gringauz; Yechiel Lamash; Alain Vlassenbroek; Alexander A Fingerle; Ernst J Rummeny; Martin Dobritz
Journal:  Eur Radiol       Date:  2012-10-19       Impact factor: 5.315

9.  Prospective evaluation of suspected stenoocclusive disease of the intracranial artery: combined MR angiography and CT angiography compared with digital subtraction angiography.

Authors:  Toshinori Hirai; Yukunori Korogi; Ken Ono; Masafumi Nagano; Kousei Maruoka; Shozaburo Uemura; Mutsumasa Takahashi
Journal:  AJNR Am J Neuroradiol       Date:  2002-01       Impact factor: 3.825

10.  Vascular applications of Spiral CT : an initial Experience.

Authors:  A Alam; B N Chander
Journal:  Med J Armed Forces India       Date:  2011-07-21
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.