Literature DB >> 8497620

Human coronary arteries: projection angiograms reconstructed from breath-hold two-dimensional MR images.

R R Edelman1, W J Manning, J Pearlman, W Li.   

Abstract

The authors sought to render projection magnetic resonance (MR) angiograms depicting a substantial length of human coronary arteries from sequential breath-hold two-dimensional MR images. Tomographic images of the right and left anterior descending coronary arteries were collected with use of a segmented gradient-recalled sequence that incorporated fat suppression and prone positioning of the patient over a surface coil. After editing the images to eliminate overlapping chamber signals and after realigning the images, a maximum-intensity-projection algorithm was applied to create projection angiograms. For the 10 coronary arteries without severe narrowing, visualized length with projection MR angiography was 109 mm +/- 29 (mean +/- standard error of estimate) versus 121 mm +/- 29 with conventional coronary angiography (ranges, 62-147 mm and 70-180 mm, respectively). At conventional angiography linear regression indicated vessel length to be 1.03 times the length depicted at MR angiography with good correlation (r = .8). Results indicate good correlation between measurements of vessel length with both conventional and MR angiography.

Entities:  

Mesh:

Year:  1993        PMID: 8497620     DOI: 10.1148/radiology.187.3.8497620

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  5 in total

1.  The intravascular contrast agent Clariscan (NC 100150 injection) for 3D MR coronary angiography in patients with coronary artery disease.

Authors:  C Klein; E Nagel; B Schnackenburg; A Bornstedt; S Schalla; V Hoffmann; A Lehning; E Fleck
Journal:  MAGMA       Date:  2000-11       Impact factor: 2.310

2.  3D motion adapted gating (3D MAG): a new navigator technique for accelerated acquisition of free breathing navigator gated 3D coronary MR-angiography.

Authors:  M Hackenbroch; K Nehrke; J Gieseke; C Meyer; K Tiemann; H Litt; O Dewald; C P Naehle; H Schild; T Sommer
Journal:  Eur Radiol       Date:  2005-04-07       Impact factor: 5.315

3.  Value of navigator echo magnetic resonance angiography in detecting occlusion/patency of arterial and venous, single and sequential coronary bypass grafts.

Authors:  G Molinari; F Sardanelli; F Zandrino; M Balbi; M A Masperone
Journal:  Int J Card Imaging       Date:  2000-06

Review 4.  Imaging of coronary atherosclerosis and identification of the vulnerable plaque.

Authors:  P J de Feyter; P W Serruys; K Nieman; N Mollet; F Cademartiri; R J van Geuns; C Slager; A F W van der Steen; R Krams; J A Schaar; P Wielopolski; P M T Pattynama; A Arampatzis; A van der Lugt; E Regar; J Ligthart; P Smits
Journal:  Neth Heart J       Date:  2003-09       Impact factor: 2.380

5.  Magnetic resonance coronary angiography using navigator echo gated real-time slice following.

Authors:  J N Oshinski; L Hofland; W T Dixon; R I Pettigrew
Journal:  Int J Card Imaging       Date:  1998-06
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.