Backscatter into the beam monitor chamber: implications for dosimetry of asymmetric collimators.

C Duzenli1, B McClean, C Field.   

Abstract

Backscatter from the asymmetric collimators of a linac into the beam monitor chamber (BMC) has been investigated for two accelerators having different BMC configurations. The effect has been quantified as a function of field size and collimator jaw position for 6 and 18 MV beams. The results indicate a maximum 2.5% (6 MV) and 4% (18 MV) decrease in output in one case and a negligible effect in the other case. The experiments indicate that the difference can be attributed to the different construction of the BMC's for the two accelerators.

Entities:  

Mesh:

Year:  1993        PMID: 8497223     DOI: 10.1118/1.597077

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  6 in total

1.  Experimental evaluations of head scatter factor calculation by use of a Gaussian function.

Authors:  Ryoichi Notake; Yukishige Kyuuma; Kouji Sasamori; Makoto Sagawa; Yasushi Annaka; Hidetoshi Saitoh; Hitoshi Shibuya
Journal:  Radiol Phys Technol       Date:  2013-12-10

2.  Prediction of back-scatter radiations to a beam monitor chamber of medical linear accelerators by use of the digitized target-current-pulse analysis method.

Authors:  Yusuke Suzuki; Naoki Hayashi; Hideki Kato; Hiroshi Fukuma; Yasujiro Hirose; Makoto Kawano; Yoshio Nishii; Masaru Nakamura; Takashi Mukouyama
Journal:  Radiol Phys Technol       Date:  2012-10-25

3.  Quantitative analysis of in-air output ratio.

Authors:  Hisayuki Miyashita; Shogo Hatanaka; Yukio Fujita; Shimpei Hashimoto; Atsushi Myojyoyama; Hidetoshi Saitoh
Journal:  J Radiat Res       Date:  2013-01-04       Impact factor: 2.724

4.  Measurement of back-scattered radiation from micro multileaf collimator into the beam monitor chamber from a dual energy linear accelerator.

Authors:  K R Muralidhar; P Narayana Murthy; N V N M Sresty; Pramod Kumar Dixit; Rajneesh Kumar; A K Raju
Journal:  J Med Phys       Date:  2007-04

5.  Jaw position uncertainty and adjacent fields in breast cancer radiotherapy.

Authors:  Emma Hedin; Anna Bäck; Roumiana Chakarova
Journal:  J Appl Clin Med Phys       Date:  2015-11-08       Impact factor: 2.102

6.  Monte Carlo modeling of HD120 multileaf collimator on Varian TrueBeam linear accelerator for verification of 6X and 6X FFF VMAT SABR treatment plans.

Authors:  Alanah M Bergman; Ermias Gete; Cheryl Duzenli; Tony Teke
Journal:  J Appl Clin Med Phys       Date:  2014-05-08       Impact factor: 2.102

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.