Literature DB >> 8496218

Unstable intertrochanteric fracture of the femur. A prospective randomised study comparing anatomical reduction and medial displacement osteotomy.

A L Desjardins1, A Roy, G Paiement, N Newman, F Pedlow, D Desloges, R E Turcotte.   

Abstract

We conducted a prospective randomised trial to compare the results of anatomical reduction and medial displacement osteotomy in 127 consecutive patients with unstable intertrochanteric fractures, of whom 109 completed the study. After an average follow-up of 11 months, we found no significant differences in walking ability, social status or failure of fixation in the two groups. Postoperative complication rates and the early mortality rate were not significantly different, but operating time and blood loss were significantly higher in the osteotomy group. With the use of modern sliding hip screws, medial displacement osteotomy is rarely indicated for unstable intertrochanteric fractures.

Entities:  

Mesh:

Year:  1993        PMID: 8496218     DOI: 10.1302/0301-620X.75B3.8496218

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  5 in total

Review 1.  Osteotomy, compression and other modifications of surgical techniques for internal fixation of extracapsular hip fractures.

Authors:  Martyn J Parker; Helen H G Handoll
Journal:  Cochrane Database Syst Rev       Date:  2009-04-15

2.  Clinical Outcomes of Intramedullary and Extramedullary Fixation in Unstable Intertrochanteric Fractures: A Randomized Clinical Trial.

Authors:  Ali Andalib; Mohammadreza Etemadifar; Pedram Yavari
Journal:  Arch Bone Jt Surg       Date:  2020-03

3.  Clinical and functional outcomes of the PCCP study: a multi-center prospective study in Italy.

Authors:  G Antonini; R Giancola; D Berruti; E Blanchietti; P Pecchia; V Francione; P Greco; T C Russo; L Pietrogrande
Journal:  Strategies Trauma Limb Reconstr       Date:  2013-03-31

4.  Technique and early results of percutaneous reduction of sagittally unstable intertrochateric fractures.

Authors:  Young Soo Chun; Hyunsup Oh; Yoon Je Cho; Kee Hyung Rhyu
Journal:  Clin Orthop Surg       Date:  2011-08-19

5.  Static load test of the modified sliding hip screw: the DHS-AF®.

Authors:  Anderson Freitas; Hélio Ismael da Costa; Célio José Silva; Carlos Henrique da Costa Rangel
Journal:  Acta Ortop Bras       Date:  2013       Impact factor: 0.513

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.