Literature DB >> 8493733

[Experimental evaluation of various anchoring techniques for synthetic ligaments].

R Letsch1, J M Garcia-Schürmann.   

Abstract

One of the weak points of augmentation or replacement of cruciate ligaments by synthetic material is the fixation of these artificial ligaments to the bone. The present investigation examines the mechanical properties of a newly developed anchoring technique (ligament fixation device = LFD) in regard to linear and maximum load, stiffness, creep, and long-term durability compared to single staples, double staples in belt buckle technique, and passing the ligament through an additional bone tunnel. The tests are carried out on cadaver knees and plastic bones under standardized conditions with the same artificial ligament in all experiments (Trevira hochfest). The LFD shows a linear load of 1866 N in cadaver knees and 1874 N in plastic bones. The stiffness is 68.3 N/mm respectively 51.9 N/mm, the elongation at 500 N load 12.7 mm respectively 10.9 mm. In the hysteresis tests with submaximum loads the ligament/LFD-unit lasts 8515 cycles in the plastic bone and 4431 cycles in the cadaver knee. These results are significantly superior to all other fixation techniques concerning linear load, stiffness and long-term durability. They permit aggressive functional treatment and immediate postoperative weight bearing of the operated knee.

Mesh:

Year:  1993        PMID: 8493733     DOI: 10.1007/BF02588085

Source DB:  PubMed          Journal:  Unfallchirurgie        ISSN: 0340-2649


  17 in total

1.  Tensile properties of the human femur-anterior cruciate ligament-tibia complex. The effects of specimen age and orientation.

Authors:  S L Woo; J M Hollis; D J Adams; R M Lyon; S Takai
Journal:  Am J Sports Med       Date:  1991 May-Jun       Impact factor: 6.202

2.  Late breakage of orthopaedic staple causing peroneal nerve palsy.

Authors:  J D Thomson; C J Talbert; J P Jackson
Journal:  Am J Sports Med       Date:  1990 Jan-Feb       Impact factor: 6.202

3.  [Fixation of a cruciate ligament replacement. Experimental evaluation of mechanical stability in cadaver knees].

Authors:  R Schabus
Journal:  Unfallchirurg       Date:  1988-05       Impact factor: 1.000

4.  Load tolerance, security, and failure modes of fixation devices for synthetic knee ligaments.

Authors:  L Good; S D Tarlow; M Odensten; J Gillquist
Journal:  Clin Orthop Relat Res       Date:  1990-04       Impact factor: 4.176

5.  The combined anterior cruciate and medial collateral ligament replacement by various materials: a comparative animal study.

Authors:  L Claes; L Dürselen; H Kiefer; W Mohr
Journal:  J Biomed Mater Res       Date:  1987-12

6.  Measurement of stability of the knee and ligament force after implantation of a synthetic anterior cruciate ligament. In vitro measurement.

Authors:  R C More; K L Markolf
Journal:  J Bone Joint Surg Am       Date:  1988-08       Impact factor: 5.284

7.  The strength of artificial ligament anchorages. A comparative experimental study.

Authors:  A A Amis
Journal:  J Bone Joint Surg Br       Date:  1988-05

8.  Soft tissue fixation to bone.

Authors:  D B Robertson; D M Daniel; E Biden
Journal:  Am J Sports Med       Date:  1986 Sep-Oct       Impact factor: 6.202

9.  A biomechanical comparison of different surgical techniques of graft fixation in anterior cruciate ligament reconstruction.

Authors:  M Kurosaka; S Yoshiya; J T Andrish
Journal:  Am J Sports Med       Date:  1987 May-Jun       Impact factor: 6.202

10.  Biomechanical analysis of human ligament grafts used in knee-ligament repairs and reconstructions.

Authors:  F R Noyes; D L Butler; E S Grood; R F Zernicke; M S Hefzy
Journal:  J Bone Joint Surg Am       Date:  1984-03       Impact factor: 5.284

View more
  3 in total

1.  [Replacement of the anterior cruciate ligament by a PET prosthesis (Trevira extra-strength) as a salvage procedure in chronically unstable previously operated knee joints. Intermediate to long-term results of a clinical study].

Authors:  R Letsch; K M Stürmer; H J Kock; H Wissing; K P Schmit-Neuerburg
Journal:  Unfallchirurgie       Date:  1994-12

Review 2.  Anterior cruciate ligament reconstruction with synthetic grafts. A review of literature.

Authors:  Claudio Legnani; Alberto Ventura; Clara Terzaghi; Enrico Borgo; Walter Albisetti
Journal:  Int Orthop       Date:  2010-02-16       Impact factor: 3.075

3.  Comparative evaluation of different anchoring techniques for synthetic cruciate ligaments. A biomechanical and animal investigation.

Authors:  R Letsch
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  1994       Impact factor: 4.342

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.