Apparent change in cardiac geometry during single-photon emission tomography thallium-201 acquisition: a complex phenomenon.

R L Eisner1, A M Aaron, M R Worthy, A S Boyers, A R Leon, W A Fajman, R E Patterson.   

Abstract

We investigated the frequency and extent of changes in heart position and geometry independent of body motion during stress single-photon emission tomography (SPET) thallium-201 myocardial perfusion imaging. Following an exercise treadmill test, patients had a 22.1-min SPET acquisition which was followed immediately by a static image acquisition for 1 min with the camera position identical to the first view of the SPET study. Point sources were placed on the body to monitor patient motion. Cardiac motion was assessed by an approach which mimicked a cross-correlation technique applied to cardiac count profiles along the horizontal and vertical directions from the first view of the SPET study and the static image. A large percentage (87.5%) of cases had some degree of horizontal or vertical motion. Pixel shifts in cardiac position of > or = 2 pixels (12 mm) occurred in 60% of patients. In 37% of patients who moved the cardiac motion was consistent with simple translation of the heart and thus amenable to correction using proposed SPET motion-correction programs. The peak heart rate achieved during stress and the ratio of the heart rate immediately before SPET acquisition to the resting heart rate were determined to be independent predictors of patient motion during SPET acquisition. Cardiac motion changes were minimal at (13.3 +/- 2.2) min after cessation of exercise. The implications of these findings for the accuracy of SPET 201Tl require further investigation.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8491225     DOI: 10.1007/BF00169808

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  5 in total

1.  "Upward creep" of the heart: a frequent source of false-positive reversible defects during thallium-201 stress-redistribution SPECT.

Authors:  J Friedman; K Van Train; J Maddahi; A Rozanski; F Prigent; J Bietendorf; A Waxman; D S Berman
Journal:  J Nucl Med       Date:  1989-10       Impact factor: 10.057

2.  Correction for patient and organ movement in SPECT: application to exercise thallium-201 cardiac imaging.

Authors:  W J Geckle; T L Frank; J M Links; L C Becker
Journal:  J Nucl Med       Date:  1988-04       Impact factor: 10.057

3.  Left ventricular performance during muscular exercise in patients with and without cardiac dysfunction.

Authors:  J Ross; J H Gault; D T Mason; J W Linhart; E Braunwald
Journal:  Circulation       Date:  1966-10       Impact factor: 29.690

4.  Upward creep of the heart in exercise thallium 201 single photon emission tomography: clinical relevance and a simple correction method.

Authors:  J Mester; R Weller; M Clausen; F Bitter; E Henze; R Lietzenmayer; W E Adam
Journal:  Eur J Nucl Med       Date:  1991

5.  Quantitative analysis of the tomographic thallium-201 myocardial bullseye display: critical role of correcting for patient motion.

Authors:  R Eisner; A Churchwell; T Noever; D Nowak; K Cloninger; D Dunn; W Carlson; J Oates; J Jones; D Morris
Journal:  J Nucl Med       Date:  1988-01       Impact factor: 10.057

  5 in total