Plateletpheresis: comparison of platelet yields, processing time, and white cell content with two apheresis systems.

E A Burgstaler1, A A Pineda, M A Brecher.   

Abstract

Two apheresis systems (COBE Spectra and Fenwal CS-3000 Plus with TNX-6 chamber [CS-3000 Plus]) were compared by using their yield predictors and maximum processing times in regard to platelet yields and processing times (n = 200 each). Platelet yields (n = 50 each) and white cell (WBC) content (n = 20 each) from procedures using the current software revision (3.6) on the Spectra and various interface offset (IO) settings on the CS-3000 Plus were also compared. Significantly higher median platelet yields (4.88 [range, 1.84-9.97] vs. 4.57 [range, 2.82-9.20] x 10(11) platelets) and frequency of components with > or = 6.0 x 10(11) platelets (31.5 vs. 21.5%) were found with the Spectra. In the study with Spectra and the CS-3000 Plus IO settings, IO-10 and IO-13, overall, produced the most platelets, although the differences were not significant. All Spectra collections tested had < 5 x 10(8) WBCs, and, depending on the software revision, had either 85 percent (revision 3.6) or 100 percent (revision 2.5) of components with < 5 x 10(6) WBCs. To ensure that 100 percent of components contained < 5 x 10(8) WBCs when the CS-3000 Plus was used, IO settings of 10 or less were required, and to ensure components with < 5 x 10(6) WBCs, only IO-6 could be used. Spectra and CS-3000 Plus were capable of collecting large doses of platelets (up to the equivalent of 18 units) in processing times of 67 to 100 minutes with < 5 x 10(6) WBCs.

Entities:  

Mesh:

Year:  1993        PMID: 8488542     DOI: 10.1046/j.1537-2995.1993.33593255599.x

Source DB:  PubMed          Journal:  Transfusion        ISSN: 0041-1132            Impact factor:   3.157


  3 in total

1.  Pre- and post- donation haematological values in healthy donors undergoing plateletpheresis with five different systems.

Authors:  Sudipta Sekhar Das; Rajendra Chaudhary; Sunil Kumar Verma; Shashank Ojha; Dheeraj Khetan
Journal:  Blood Transfus       Date:  2009-07       Impact factor: 3.443

2.  Comparison of Plateletpheresis on the Fenwal Amicus and Fresenius Com.Tec Cell Separators.

Authors:  Fevzi Altuntas; Ismail Sari; Ismail Kocyigit; Leylagul Kaynar; Sibel Hacioglu; Ahmet Ozturk; Mehmet Oztekin; Musa Solmaz; Bulent Eser; Mustafa Cetin; Ali Unal
Journal:  Transfus Med Hemother       Date:  2008-09-16       Impact factor: 3.747

3.  Quality assessment of platelet concentrates prepared by platelet rich plasma-platelet concentrate, buffy coat poor-platelet concentrate (BC-PC) and apheresis-PC methods.

Authors:  Ravindra P Singh; Neelam Marwaha; Pankaj Malhotra; Sumitra Dash
Journal:  Asian J Transfus Sci       Date:  2009-07
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.