Comparison of the Wang 19-gauge and 22-gauge needles in the mediastinal staging of lung cancer.

D A Schenk1, S L Chambers, S Derdak, K H Komadina, J S Pickard, P J Strollo, R E Lewis, A J Patefield, J H Henderson, S M Tomski.   

Abstract

Transbronchial needle aspiration (TBNA) offers the unique opportunity to pathologically stage patients with lung cancer at the time of diagnostic bronchoscopy. The purpose of this study was to compare the staging sensitivities of the Wang 22-gauge and 19-gauge needles. We studied 64 patients with bronchogenic carcinoma and mediastinal adenopathy. Before bronchoscopy each patient underwent chest CT. Three to four aspirates were obtained with each needle from endotracheal sites adjacent to paratracheal lymphadenopathy. In 47 patients malignant mediastinal adenopathy was confirmed by the 19-gauge needle. A total of 29 patients had malignant 22-gauge needle aspirates. Of the 64 patients, 9 had benign, reactive mediastinal lymph nodes. There were 20 patients in whom only the 19-gauge needle demonstrated malignancy and 2 patients with malignant 22-gauge needle aspirates as the sole identifier of paratracheal malignancy. As a staging tool, the 19-gauge needle was significantly more sensitive than the 22-gauge needle, 85.5 versus 52.7% (p = 0.0001). Overall, in 49 of 55 patients (89.1%) with malignant mediastinal lymphadenopathy paratracheal tumor was confirmed by TBNA. The 19-gauge TBNA staging of the mediastinum is an effective, safe, and cost-saving alternative to surgical mediastinal exploration that can be performed during initial diagnostic bronchoscopy.

Entities:  

Mesh:

Year:  1993        PMID: 8484639     DOI: 10.1164/ajrccm/147.5.1251

Source DB:  PubMed          Journal:  Am Rev Respir Dis        ISSN: 0003-0805


  12 in total

1.  British Thoracic Society guidelines on diagnostic flexible bronchoscopy.

Authors: 
Journal:  Thorax       Date:  2001-03       Impact factor: 9.139

2.  Electromagnetic navigation diagnostic bronchoscopy: a prospective study.

Authors:  Thomas R Gildea; Peter J Mazzone; Demet Karnak; Moulay Meziane; Atul C Mehta
Journal:  Am J Respir Crit Care Med       Date:  2006-07-27       Impact factor: 21.405

3.  A strategy to improve the yield of transbronchial needle aspiration.

Authors:  Ghee Chee Phua; Kyung-Jae Rhee; Mariko Koh; Chian Min Loo; Pyng Lee
Journal:  Surg Endosc       Date:  2010-02-21       Impact factor: 4.584

4.  Transtracheal aspiration using rigid bronchoscopy and a rigid needle for investigating mediastinal masses.

Authors:  M L Wilsher; A M Gurley
Journal:  Thorax       Date:  1996-02       Impact factor: 9.139

Review 5.  Accuracy of transbronchial needle aspiration for mediastinal staging of non-small cell lung cancer: a meta-analysis.

Authors:  J-E C Holty; W G Kuschner; M K Gould
Journal:  Thorax       Date:  2005-06-30       Impact factor: 9.139

6.  Diagnostic utility of conventional transbronchial needle aspiration without rapid on-site evaluation in patients with lung cancer.

Authors:  Ritika Walia; Karan Madan; Anant Mohan; Deepali Jain; Vijay Hadda; Gopi C Khilnani; Randeep Guleria
Journal:  Lung India       Date:  2014-07

7.  Prospective randomized trial to compare the safety, diagnostic yield and utility of 22-gauge and 19-gauge endobronchial ultrasound transbronchial needle aspirates and processing technique by cytology and histopathology.

Authors:  Christopher J Manley; Rohit Kumar; Yulan Gong; Min Huang; Shuanzeng Sam Wei; Rajeswari Nagarathinam; Alan Haber; Brian Egleston; Douglas Flieder; Hormoz Ehya
Journal:  J Am Soc Cytopathol       Date:  2021-10-23

8.  Utility of conventional transbronchial needle aspiration with rapid on-site evaluation (c-TBNA-ROSE) at a tertiary care center with endobronchial ultrasound (EBUS) facility.

Authors:  Neha Kawatra Madan; Karan Madan; Deepali Jain; Ritika Walia; Anant Mohan; Vijay Hadda; Sandeep Mathur; Venkateswaran K Iyer; Gopi C Khilnani; Randeep Guleria
Journal:  J Cytol       Date:  2016 Jan-Mar       Impact factor: 1.000

9.  Comparison of 19-gauge eXcelon and WANG MW-319 transbronchial aspiration needles.

Authors:  Li-Han Hsu; Chia-Chuan Liu; Jen-Sheng Ko; An-Chen Feng; Nei-Min Chu
Journal:  Thorac Cancer       Date:  2015-09-08       Impact factor: 3.500

10.  Efficacy and adequacy of conventional transbronchial needle aspiration of IASLC stations 4R, 4L and 7 using endobronchial landmarks provided by the Wang nodal mapping system in the staging of lung cancer.

Authors:  Qinghua Liu; Songyan Han; Sixto Arias; J Francis Turner; Hans Lee; Robert Browning; Ko-Pen Wang
Journal:  Thorac Cancer       Date:  2015-07-14       Impact factor: 3.500

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.