Literature DB >> 8484567

Incorporating vessel taper and compliance properties in Navier-Stokes based blood flow models.

G F Ye1, T W Moore, D Jaron.   

Abstract

A popular and useful technique used to model blood flow in cardiovascular simulations is to divide each blood vessel into a series of segments, each with its own lumped resistance, inertance, and compliance parameters. The values of these parameters are usually obtained through a simplification of the Navier-Stokes equations for fluid flow. However, the simplification often ignores the nonlinear and convective terms of the equations, resulting in errors in the parameter values, especially in the value found for resistance per unit length. We report a new method for the calculation of vessel resistance per unit length which takes into account the effects of vessel taper and wall compliance. It is shown that these effects can be addressed by the addition of two time-varying terms to the calculation of resistance per unit length. One term, due to vessel taper, is proportional to volumetric flow rate Q. The other term, due to vessel compliance, is proportional to delta p/delta t. These variables are readily available in computer simulations of blood flow in lumped parameter systems. Using data for the descending aorta, the new parameter values, when averaged over a cardiac cycle, compare favorably with results in the literature.

Mesh:

Year:  1993        PMID: 8484567     DOI: 10.1007/bf02367605

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  14 in total

1.  A catheter tip method for measurement of the instantaneous aortic blood velocity.

Authors:  A G CASPER; D L FRY; A J MALLOS
Journal:  Circ Res       Date:  1956-09       Impact factor: 17.367

2.  Analog studies of the human systemic arterial tree.

Authors:  N Westerhof; F Bosman; C J De Vries; A Noordergraaf
Journal:  J Biomech       Date:  1969-05       Impact factor: 2.712

3.  Cardiac energy considerations during intraaortic balloon pumping.

Authors:  O Barnea; T W Moore; S E Dubin; D Jaron
Journal:  IEEE Trans Biomed Eng       Date:  1990-02       Impact factor: 4.538

4.  A study on the non-linear flow of blood through arteries.

Authors:  J C Misra; S I Singh
Journal:  Bull Math Biol       Date:  1987       Impact factor: 1.758

5.  Nonlinear analysis of aortic flow in living dogs.

Authors:  S C Ling; H B Atabek; W G Letzing; D J Patel
Journal:  Circ Res       Date:  1973-08       Impact factor: 17.367

6.  Measurement and utilization of in vivo blood-pressure transfer functions of dog and chicken aortas.

Authors:  J J Strano; W Welkowitz; S Fich
Journal:  IEEE Trans Biomed Eng       Date:  1972-07       Impact factor: 4.538

7.  Synchronized external pulsation for improved tolerance to acceleration stress: model studies and preliminary experiments.

Authors:  T W Moore; D Jaron; C L Chu; U Dinnar; L Hrebien; M J White; E Hendler; S Dubin
Journal:  IEEE Trans Biomed Eng       Date:  1985-02       Impact factor: 4.538

8.  Pressure gradient related to energy conversion in the aorta.

Authors:  J Melbin; A Noordergraaf
Journal:  Circ Res       Date:  1983-02       Impact factor: 17.367

9.  Analysis of non-linear pulsatile blood flow in arteries.

Authors:  K Imaeda; F O Goodman
Journal:  J Biomech       Date:  1980       Impact factor: 2.712

10.  Experimental determination of wall shear rate in canine carotid arteries perfused in vitro.

Authors:  G A Johnson; T K Hung; A M Brant; H S Borovetz
Journal:  J Biomech       Date:  1989       Impact factor: 2.712

View more
  2 in total

1.  In vitro and finite-element model investigation of the conductance technique for measurement of aortic segmental volume.

Authors:  D A Hettrick; J H Battocletti; J J Ackmann; J H Linehan; D C Warltier
Journal:  Ann Biomed Eng       Date:  1996 Nov-Dec       Impact factor: 3.934

2.  Patient-specific structural effects on hemodynamics in the ischemic lower limb artery.

Authors:  Pengcheng Xu; Xin Liu; Qi Song; Guishan Chen; Defeng Wang; Heye Zhang; Li Yan; Dan Liu; Wenhua Huang
Journal:  Sci Rep       Date:  2016-12-15       Impact factor: 4.379

  2 in total