Literature DB >> 8478705

Immediate thallium-201 reinjection following stress imaging: a time-saving approach for detection of myocardial viability.

B L van Eck-Smit1, E E van der Wall, A F Kuijper, A H Zwinderman, E K Pauwels.   

Abstract

Thallium-201 reinjection following 3-4-hr redistribution imaging improves the detection of viable myocardium but considerably prolongs the total investigation time. We compared the results of immediate 201Tl reinjection with 3-hr redistribution imaging in 120 consecutive patients who were evaluated for myocardial ischemia. Thallium-201 was reinjected immediately following the postexercise study. The images were acquired 1 hr later and reacquired at 3 hr redistribution. A total of 960 segments per imaging series were evaluated, of which 320 (33%) segments showed perfusion defects on the post-exercise images. On the 1-hr images, 220 (69%) segments demonstrated enhanced thallium uptake, 97 (30%) segments did not change and 3 (1%) segments showed reverse redistribution. Of the 100 (97 + 3) persistent defects, only 12 (4%) segments showed fill-in of 201Tl on 3 hr redistribution images. A total of 49 (15%) segments showed reverse redistribution. Defects on postexercise images were seen in 95 patients (79%) of whom 9 (10%) showed no change on immediate reinjection images. In only 1 (1%) patient was the diagnosis changed from myocardial necrosis to myocardial ischemia after analysis of the 3-hr redistribution images. These data indicate that immediate postexercise reinjection of 201Tl followed by 1-hr image acquisition may be superior to 3-hr redistribution imaging in identifying viable myocardium in patients evaluated for myocardial ischemia. This protocol eliminates the need for an additional series of 3-4-hr redistribution images and offers the advantages of reduced total imaging time, improved convenience for the patient and increased patient throughput.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8478705

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  21 in total

1.  The accuracy of 1-day dual-isotope myocardial SPECT in a population with high prevalence of coronary artery disease.

Authors:  Reginald G E J Groutars; J Fred Verzijlbergen; Monique M C Tiel-van Buul; Aeilco H Zwinderman; Carl A P L Ascoop; Norbert M van Hemel; Ernst E van der Wall
Journal:  Int J Cardiovasc Imaging       Date:  2003-06       Impact factor: 2.357

2.  Rabbit models: ideal for imaging purposes?

Authors:  A van der Laarse; E E van der Wall
Journal:  Int J Cardiovasc Imaging       Date:  2008-12-16       Impact factor: 2.357

3.  Single injection, double acquisition: a double-edged sword?

Authors:  Ernst E van der Wall; Yves G America; Arthur J Scholte; Jeroen J Bax
Journal:  Int J Cardiovasc Imaging       Date:  2008-07-24       Impact factor: 2.357

4.  Reinjection of thallium for detection of viable myocardium: why not do it immediately?

Authors:  B L van Eck-Smit; E E van der Wall
Journal:  Br Heart J       Date:  1995-08

5.  Early reinjection of thallium-201 after stress imaging.

Authors:  M Galli; C Marcassa
Journal:  Eur J Nucl Med       Date:  1996-08

6.  Comparative accuracy of various Tl-201 reinjection imaging protocols to detect myocardial viability.

Authors:  H Naruse; T Kondo; T Arii; M Morita; M Ohyanagi; T Iwasaki; M Fukuchi
Journal:  Ann Nucl Med       Date:  1996-02       Impact factor: 2.668

Review 7.  The maze of myocardial perfusion imaging protocols in 1994.

Authors:  F J Wackers
Journal:  J Nucl Cardiol       Date:  1994 Mar-Apr       Impact factor: 5.952

8.  Clearance of thallium-201 from the peripheral blood: comparison of immediate and standard thallium-201 reinjection.

Authors:  B L van Eck-Smit; E E van der Wall; P P Verhoeven; S Poots; A H Zwinderman; E K Pauwels
Journal:  Eur J Nucl Med       Date:  1996-02

9.  Defect reversibility using thallium-201 reinjection. Comparison of stress-redistribution-reinjection with stress-immediate reinjection.

Authors:  B L van Eck-Smit; A F Kuijper; A H Zwinderman; A V Bruschke; E K Pauwels; E E van der Wall
Journal:  Int J Card Imaging       Date:  1996-03

10.  Positron emission tomography; viable tool in patients pre-CABG?

Authors:  E E van der Wall; H M Siebelink; A J Scholte; J J Bax
Journal:  Int J Cardiovasc Imaging       Date:  2010-04-01       Impact factor: 2.357

View more