Right femoral, cortical bone osteotomies of 42 rabbits were fixed with fibrillated, self-reinforced (SR) poly-L-lactide (PLLA) rods, 4.5 mm in diameter. Follow-up times were from 3 to 48 wk. None of the rods broke during this period. There was one non-union at three weeks and one non-union at 12 weeks. Radiographic, histologic, microradiographic and oxytetracyclic fluorescence studies showed normal healing. Shear load carrying capacity of the osteotomy plane was measured from 30 bone samples; the shear force at breaking increased during the follow-up time to 450 N, while the mean shear force of intact, left-side control femurs was 440 N. Before shear tests of the bones, the SR-PLLA rods were taken away from the medullary cavities of the femurs. The rods were also tested mechanically. About 25% of the initial 136 MPa shear-strength of the rods was left after 24 wk. The results show that fibrillated SR-PLLA rods are strong enough to be used in intramedullary nailing of femoral cortical bone osteotomies in rabbits.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8477000     DOI: 10.1016/0142-9612(93)90123-j

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  5 in total

1.  Tissue restoration after implantation of polyglycolide, polydioxanone, polylevolactide, and metallic pins in cortical bone: an experimental study in rabbits.

Authors:  Harri K Pihlajamäki; Sari T Salminen; Olli Tynninen; Ole M Böstman; Outi Laitinen
Journal:  Calcif Tissue Int       Date:  2010-05-22       Impact factor: 4.333

2.  Synthesis and properties of poly(lactic acid).

Authors:  A G Andreopoulos; E Hatzi; M Doxastakis
Journal:  J Mater Sci Mater Med       Date:  1999-01       Impact factor: 3.896

3.  Controlled release of salicylic acid from poly(D,L-Lactide).

Authors:  A G Andreopoulos; E Hatzi; M Doxastakis
Journal:  J Mater Sci Mater Med       Date:  2001-03       Impact factor: 3.896

4.  Shear-load carrying capacities of the distal rat femora after osteotomy fixed with self-reinforced polyglycolic acid and poly-L-lactic acid pins.

Authors:  Pia Nordström; Timo Pohjonen; Pertti Törmälä; Pentti Rokkanen
Journal:  J Mater Sci Mater Med       Date:  2002-01       Impact factor: 3.896

5.  Material properties of absorbable self-reinforced fibrillated poly-96L/4 D-lactide (SR-PLA96) rods; a study in vitro and in vivo.

Authors:  A Saikku-Bäckström; R M Tulamo; T Pohjonen; P Törmälä; J E Räihä; P Rokkanen
Journal:  J Mater Sci Mater Med       Date:  1999-01       Impact factor: 3.896

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.