Literature DB >> 8476988

Cartilage mechanics and morphology, synovitis and proteoglycan fragments in rabbit joint fluid after prosthetic meniscal substitution.

K Messner1, L S Lohmander, J Gillquist.   

Abstract

The effects of meniscal substitution with a Dacron or Teflon prosthesis on rabbit knee-joint cartilage were studied by indentation tests, gross and histological inspection, analysis of proteoglycan fragments in joint fluid and an evaluation of synovial changes. Cartilage mechanics and cartilage morphology were similarly abnormal after meniscectomy and meniscal substitution. The elevated concentrations of proteoglycan fragments in joint fluid and the more severe synovial changes in joints with a meniscal substitute, as compared to meniscectomy, probably resulted from irritation of the artificial implant, but also reflected the remaining effects from the necessary bone drilling. In this short-term experiment, the use of an artificial meniscal substitute could not prevent cartilage degeneration after meniscectomy.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8476988     DOI: 10.1016/0142-9612(93)90018-w

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  6 in total

Review 1.  Synthetic meniscus replacement: a review.

Authors:  Anne Christiane Theodora Vrancken; Pieter Buma; Tony George van Tienen
Journal:  Int Orthop       Date:  2012-10-26       Impact factor: 3.075

2.  Synovial reaction and concentrations of proteoglycan fragments in joint fluid after intraarticular knee injuries.

Authors:  K Messner; J Gao
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  1995       Impact factor: 4.342

3.  Short Term Evaluation of an Anatomically Shaped Polycarbonate Urethane Total Meniscus Replacement in a Goat Model.

Authors:  A C T Vrancken; W Madej; G Hannink; N Verdonschot; T G van Tienen; P Buma
Journal:  PLoS One       Date:  2015-07-20       Impact factor: 3.240

4.  Meniscal Scaffolds - Preclinical Evidence to Support their Use: A Systematic Review.

Authors:  Berardo Di Matteo; Francesco Perdisa; Natalia Gostynska; Elizaveta Kon; Giuseppe Filardo; Maurilio Marcacci
Journal:  Open Orthop J       Date:  2015-05-15

5.  BIORESORBABLE POLYMERIC MENISCAL PROSTHESIS: STUDY IN RABBITS.

Authors:  Tulio Pereira Cardoso; Eliana Aparecida de Rezende Duek; Marco Martins Amatuzzi; Edie Benedito Caetano
Journal:  Rev Bras Ortop       Date:  2015-11-17

6.  Evaluating the effects of material properties of artificial meniscal implant in the human knee joint using finite element analysis.

Authors:  Duraisamy Shriram; Gideon Praveen Kumar; Fangsen Cui; Yee Han Dave Lee; Karupppasamy Subburaj
Journal:  Sci Rep       Date:  2017-07-20       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.