Literature DB >> 8470715

Corneal light scattering and visual performance in myopic individuals with spectacles, contact lenses, or excimer laser photorefractive keratectomy.

C P Lohmann1, F Fitzke, D O'Brart, M K Muir, G Timberlake, J Marshall.   

Abstract

Corneal transparency and visual performance are currently receiving much attention after excimer laser surgery. To date, emphasis has been on comparison of eyes on which laser surgery has been performed to eyes with emmetropia. A more appropriate comparison should be between eyes on which laser surgery has been performed and eyes with other forms of correction for myopia. Forward-scattered light, back-scattered light, and visual acuity were investigated and data were collected from 35 myopic individuals with various types of correction for myopia (spectacles, hard and soft contact lenses, and excimer laser surgery). Forward-scattered light was measured by using a new computerized technique, back-scattered light was measured with a charge coupled device-camera system, and visual acuity was measured with a computerized system at various levels of contrast. Spectacles, hard contact lenses, and excimer laser surgery are all superior to soft contact lenses in terms of light scatter and low-contrast visual acuity and excimer laser photorefractive keratectomy produces comparable results to spectacles one year postoperatively. At low-contrast visual acuity, mean visual acuity was 2.45 minutes of arc for the spectacle wearers, 3.21 minutes of arc for the hard contact-lens wearers, and 5.04 minutes of arc for the soft contact-lens wearers. Excimer laser patients had a mean visual acuity of 9.04 minutes of arc three months postoperatively, and 2.53 minutes of arc after one year. A mean value of 2.4% contrast for forward light scatter was obtained for spectacle wearers compared with a level of 3.84% contrast for hard contact-lens wearers and 16.1% contrast for soft contact-lens wearers. The mean value for excimer laser patients was 20% contrast three months postoperatively and 2.1% contrast one year postoperatively.

Entities:  

Mesh:

Year:  1993        PMID: 8470715     DOI: 10.1016/s0002-9394(14)74445-9

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  10 in total

1.  [Frankfurt-Freiburg Contrast and Acuity Test System (FF-CATS). A new test to determine contrast sensitivity under variable ambient and glare luminance levels].

Authors:  E Terzi; J Bühren; W Wesemann; T Kohnen
Journal:  Ophthalmologe       Date:  2005-05       Impact factor: 1.059

2.  Wound healing anomalies after excimer laser photorefractive keratectomy: correlation of clinical outcomes, corneal topography, and confocal microscopy.

Authors:  R F Steinert
Journal:  Trans Am Ophthalmol Soc       Date:  1997

3.  Quantifying intraocular scatter with near diffraction-limited double-pass point spread function.

Authors:  Junlei Zhao; Fei Xiao; Jian Kang; Haoxin Zhao; Yun Dai; Yudong Zhang
Journal:  Biomed Opt Express       Date:  2016-10-17       Impact factor: 3.732

4.  Gas permeable and soft contact lens wear in children.

Authors:  Lisa A Jones-Jordan; Jeffrey J Walline; Donald O Mutti; Marjorie J Rah; Kelly K Nichols; Jason J Nichols; Karla Zadnik
Journal:  Optom Vis Sci       Date:  2010-06       Impact factor: 1.973

5.  Stray light in photorefractive keratectomy for myopia.

Authors:  H G Veraart; T J van den Berg; R Hennekes; A M Adank
Journal:  Doc Ophthalmol       Date:  1995       Impact factor: 2.379

6.  Resolution of calcific band keratopathy after lowering elevated serum calcium in a patient with sarcoidosis.

Authors:  R L Johnston; M R Stanford; S Verma; W T Green; E M Graham
Journal:  Br J Ophthalmol       Date:  1995-11       Impact factor: 4.638

7.  Identical excimer laser PTK treatments in rabbits result in two distinct haze responses.

Authors:  Russell L McCally; Patrick J Connolly; Walter J Stark; Sandeep Jain; Dimitri T Azar
Journal:  Invest Ophthalmol Vis Sci       Date:  2006-10       Impact factor: 4.799

8.  Treatment of band keratopathy by excimer laser phototherapeutic keratectomy: surgical techniques and long term follow up.

Authors:  D P O'Brart; D S Gartry; C P Lohmann; A L Patmore; M G Kerr Muir; J Marshall
Journal:  Br J Ophthalmol       Date:  1993-11       Impact factor: 4.638

9.  Changes in forward light scatter parameters as a function of refractive error in young adults.

Authors:  Manbir Nagra; Mansi Patel; John Barbur
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2020-01-07       Impact factor: 3.117

10.  Effect of Varying Levels of Glare on Contrast Sensitivity Measurements of Young Healthy Individuals Under Photopic and Mesopic Vision.

Authors:  Marcello Maniglia; Steven M Thurman; Aaron R Seitz; Pinakin G Davey
Journal:  Front Psychol       Date:  2018-06-14
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.