Literature DB >> 8468507

Pre-clinical evaluation of a microwave planar array applicator for superficial hyperthermia.

C J Diederich1, P R Stauffer.   

Abstract

Multi-element hyperthermia applicators have an advantage over single-aperture devices in that the power deposition pattern across the applicator surface may be adjusted to improve the resultant temperature distribution. This capability can be used to compensate for irregular tumour geometry as well as heterogeneity of thermal and power absorption parameters within the tissue. This paper evaluates the first commercially available microwave system of this type designed for superficial hyperthermia. The applicator (16-element planar array, 915 MHz, 15.2 x 15.2 cm footprint) was evaluated by the following: (1) measuring absolute SAR distributions in muscle-equivalent liquid phantom with an intervening 1 cm thick layer of fat phantom by scanning a calibrated E-field sensor, and (2) power output measurements using calorimetric methods. The SAR distributions measured for each individual aperture exhibited significant irregularities and differing power deposition patterns. A priori knowledge of these different power deposition characteristics was used to provide appropriate illumination schemes which could be used as initial starting points for producing clinically useful power deposition patterns. Measurements of these composite patterns demonstrate the adjustable nature and flexibility of the heating capabilities of this applicator, which includes 50% iso-SAR coverage that can be extended to the applicator perimeter. This clearly illustrates the clinical utility and potential advantages of this system over single-aperture devices for superficial hyperthermia.

Entities:  

Mesh:

Year:  1993        PMID: 8468507     DOI: 10.3109/02656739309022537

Source DB:  PubMed          Journal:  Int J Hyperthermia        ISSN: 0265-6736            Impact factor:   3.914


  5 in total

1.  Performance evaluation of a conformal thermal monitoring sheet sensor array for measurement of surface temperature distributions during superficial hyperthermia treatments.

Authors:  K Arunachalam; P Maccarini; T Juang; C Gaeta; P R Stauffer
Journal:  Int J Hyperthermia       Date:  2008-06       Impact factor: 3.914

Review 2.  Conformal microwave array (CMA) applicators for hyperthermia of diffuse chest wall recurrence.

Authors:  Paul R Stauffer; Paolo Maccarini; Kavitha Arunachalam; Oana Craciunescu; Chris Diederich; Titania Juang; Francesca Rossetto; Jaime Schlorff; Andrew Milligan; Joe Hsu; Penny Sneed; Zeljko Vujaskovic
Journal:  Int J Hyperthermia       Date:  2010       Impact factor: 3.914

3.  A thermal monitoring sheet with low influence from adjacent waterbolus for tissue surface thermometry during clinical hyperthermia.

Authors:  Kavitha Arunachalam; Paolo F Maccarini; Paul R Stauffer
Journal:  IEEE Trans Biomed Eng       Date:  2008-10       Impact factor: 4.538

4.  Microwave Radiometry for Non-Invasive Detection of Vesicoureteral Reflux (VUR) Following Bladder Warming.

Authors:  Paul R Stauffer; Paolo F Maccarini; Kavitha Arunachalam; Valeria De Luca; Sara Salahi; Alina Boico; Oystein Klemetsen; Yngve Birkelund; Svein K Jacobsen; Fernando Bardati; Piero Tognolatti; Brent Snow
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2011-02-22

Review 5.  Quality assurance guidelines for superficial hyperthermia clinical trials : II. Technical requirements for heating devices.

Authors:  Hana Dobšíček Trefná; Johannes Crezee; Manfred Schmidt; Dietmar Marder; Ulf Lamprecht; Michael Ehmann; Jacek Nadobny; Josefin Hartmann; Nicolleta Lomax; Sultan Abdel-Rahman; Sergio Curto; Akke Bakker; Mark D Hurwitz; Chris J Diederich; Paul R Stauffer; Gerard C Van Rhoon
Journal:  Strahlenther Onkol       Date:  2017-03-01       Impact factor: 3.621

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.