Literature DB >> 8466397

Accurate enzyme activity measurements. Two decades of development in the commutability of enzyme quality control materials.

R Rej1.   

Abstract

Commercial serum preparations are integral components of both internal and external quality control programs for enzyme activity measurements. However, properties of these materials may differ significantly from those of clinical specimens. Differences from clinical specimens may include the following: species origin of the enzyme; isoenzyme form(s); integrity of the molecular species; matrix of the solution; processes such as lyophilization; and addition of preservatives. There are also significant differences among methods measuring the activity of a single enzyme including a diversity of compounds that may serve as substrate(s); variable cofactor or metal supplementation; and differences in the substrate concentration(s), buffer substances, pH, and temperature. The measured response to each of these variations in assay technique may differ among these types of specimens. To be acceptable, quality control materials must have properties similar to those of clinical specimens. Thus, the concept of commutability that we originated and first applied to enzyme activity measurements remains useful, and its further application to the problem of "matrix effects" is reviewed here. Multivariate display techniques are applied to the specific examples of aspartate aminotransferase, alpha-amylase, and alkaline phosphatase to judge the commutability of quality control materials for these enzymes.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8466397

Source DB:  PubMed          Journal:  Arch Pathol Lab Med        ISSN: 0003-9985            Impact factor:   5.534


  4 in total

1.  Reference materials and commutability.

Authors:  Hubert W Vesper; W Gregory Miller; Gary L Myers
Journal:  Clin Biochem Rev       Date:  2007-11

2.  Traceability in clinical enzymology.

Authors:  Ilenia Infusino; Roberto Bonora; Mauro Panteghini
Journal:  Clin Biochem Rev       Date:  2007-11

3.  Feasibility study of a candidate reference material for ions in PM2.5: does commutability matter also for inorganic matrices?

Authors:  G Emma; J Snell; J Charoud-Got; A Held; H Emons
Journal:  Anal Bioanal Chem       Date:  2018-07-04       Impact factor: 4.142

4.  Standardization in Clinical Enzymology.

Authors:  Ilenia Infusino; Panteghini Mauro
Journal:  EJIFCC       Date:  2009-10-12
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.