Literature DB >> 8460807

Dural taps revisited. A 20-year survey from Birmingham Maternity Hospital.

P C Stride1, G M Cooper.   

Abstract

The records from 34,819 obstetric epidurals performed at Birmingham Maternity Hospital over the period 1969-1988 were examined. During that time there were 460 dural taps (overall incidence 1.3%). Of the methods used to detect the epidural space, loss of resistance to injection of saline was associated with the lowest incidence of dural tap (0.6%). The incidence of typical postdural puncture headache when managed conservatively was 86%. Provision of an epidural drip after delivery reduced the incidence of headache to 70%. Elective forceps delivery conferred no additional benefit, and tended to delay the onset of headache. Blood patches were performed on 135 patients and provided complete relief of headache in 93 (68%). A further 23 patients (16%) obtained partial relief.

Entities:  

Mesh:

Year:  1993        PMID: 8460807     DOI: 10.1111/j.1365-2044.1993.tb06913.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  23 in total

1.  Subcutaneous blood patch for iatrogenic suboccipital pseudomeningocele following decompressive suboccipital craniectomy and enlarging duroplasty for the treatment of Chiari I malformation. Technical note.

Authors:  G Paternoster; L Massimi; G Capone; G Tamburrini; M Caldarelli; C Di Rocco
Journal:  Childs Nerv Syst       Date:  2011-12-08       Impact factor: 1.475

Review 2.  The role of epidural anesthesia and analgesia in surgical practice.

Authors:  Robert J Moraca; David G Sheldon; Richard C Thirlby
Journal:  Ann Surg       Date:  2003-11       Impact factor: 12.969

3.  Post-dural puncture headache, intracranial air and obstetric anesthesia.

Authors:  K M Kuczkowski
Journal:  Anaesthesist       Date:  2003-09       Impact factor: 1.041

4.  Decreased incidence of headache after unintentional dural puncture in patients with cesarean delivery administered with postoperative epidural analgesia.

Authors:  Mehmet Cesur; Haci A Alici; Ali F Erdem; Fikret Silbir; Mine Celik
Journal:  J Anesth       Date:  2009-02-22       Impact factor: 2.078

5.  Observational study of changes in epidural pressure and elastance during epidural blood patch in obstetric patients.

Authors:  S D Pratt; D W Kaczka; P E Hess
Journal:  Int J Obstet Anesth       Date:  2014-01-27       Impact factor: 2.603

6.  Dural puncture and headache.

Authors:  F Reynolds
Journal:  BMJ       Date:  1993-04-03

7.  Dural puncture. Blood patch not always benign.

Authors:  G M Cooper; P C Stride
Journal:  BMJ       Date:  1993-05-15

8.  Postdural puncture headache.

Authors:  E Crosby
Journal:  CMAJ       Date:  1994-03-15       Impact factor: 8.262

9.  Accidental dural puncture in obstetric patients and long term symptoms.

Authors:  C MacArthur; M Lewis; E G Knox
Journal:  BMJ       Date:  1993-04-03

10.  Postdural puncture headache.

Authors:  Ahmed Ghaleb
Journal:  Anesthesiol Res Pract       Date:  2010-08-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.