Quantitative photoplethysmography: Lambert-Beer law or inverse function incorporating light scatter.

M Cejnar1, H Kobler, S N Hunyor.   

Abstract

Finger blood volume is commonly determined from measurement of infra-red (IR) light transmittance using the Lambert-Beer law of light absorption derived for use in non-scattering media, even when such transmission involves light scatter around the phalangeal bone. Simultaneous IR transmittance and finger volume were measured over the full dynamic range of vascular volumes in seven subjects and outcomes compared with data fitted according to the Lambert-Beer exponential function and an inverse function derived for light attenuation by scattering materials. Curves were fitted by the least-squares method and goodness of fit was compared using standard errors of estimate (SEE). The inverse function gave a better data fit in six of the subjects: mean SEE 1.9 (SD 0.7, range 0.7-2.8) and 4.6 (2.2, 2.0-8.0) respectively (p < 0.02, paired t-test). Thus, when relating IR transmittance to blood volume, as occurs in the finger during measurements of arterial compliance, an inverse function derived from a model of light attenuation by scattering media gives more accurate results than the traditional exponential fit.

Entities:  

Mesh:

Year:  1993        PMID: 8459696     DOI: 10.1016/0141-5425(93)90047-3

Source DB:  PubMed          Journal:  J Biomed Eng        ISSN: 0141-5425


  5 in total

Review 1.  Photoplethysmography Revisited: From Contact to Noncontact, From Point to Imaging.

Authors:  Yu Sun; Nitish Thakor
Journal:  IEEE Trans Biomed Eng       Date:  2015-09-15       Impact factor: 4.538

2.  Vibration plethysmography: a method for studying the visco-elastic properties of finger arteries.

Authors:  J Penaz; N Honzikova; P Jurak
Journal:  Med Biol Eng Comput       Date:  1997-11       Impact factor: 2.602

3.  Estimating Surgical Blood Loss Volume Using Continuously Monitored Vital Signs.

Authors:  Yang Chen; Chengcheng Hong; Michael R Pinsky; Ting Ma; Gilles Clermont
Journal:  Sensors (Basel)       Date:  2020-11-17       Impact factor: 3.576

4.  Real-time estimation of respiratory rate from a photoplethysmogram using an adaptive lattice notch filter.

Authors:  Chanki Park; Boreom Lee
Journal:  Biomed Eng Online       Date:  2014-12-17       Impact factor: 2.819

Review 5.  Advances in Cuffless Continuous Blood Pressure Monitoring Technology Based on PPG Signals.

Authors:  Caijie Qin; Xiaohua Wang; Guangjun Xu; Xibo Ma
Journal:  Biomed Res Int       Date:  2022-10-01       Impact factor: 3.246

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.