Transcatheter closure of Blalock-Taussig shunts with a modified Rashkind umbrella delivery system.

C Houde1, E M Zahn, L N Benson.   

Abstract

Transcatheter occlusion of Blalock-Taussig shunts was successfully performed in three children with the Rashkind double umbrella occluding device. Complete occlusion was confirmed angiographically in two patients and echocardiographically in the third. The delivery system was adapted for use through smaller sheaths making it more suitable for small children or arterial access.

Entities:  

Mesh:

Year:  1993        PMID: 8457396      PMCID: PMC1024918          DOI: 10.1136/hrt.69.1.56

Source DB:  PubMed          Journal:  Br Heart J        ISSN: 0007-0769


  7 in total

Review 1.  Pediatric and congenital therapeutic cardiac catheterization.

Authors:  C E Mullins
Journal:  Circulation       Date:  1989-06       Impact factor: 29.690

2.  Coil embolization to occlude aortopulmonary collateral vessels and shunts in patients with congenital heart disease.

Authors:  S B Perry; W Radtke; K E Fellows; J F Keane; J E Lock
Journal:  J Am Coll Cardiol       Date:  1989-01       Impact factor: 24.094

3.  Systemic-to-pulmonary collateral vessels and shunts: treatment with embolization.

Authors:  J F Lois; A S Gomes; D C Smith; H Laks
Journal:  Radiology       Date:  1988-12       Impact factor: 11.105

4.  Transcatheter umbrella closure of congenital heart defects.

Authors:  J E Lock; J T Cockerham; J F Keane; J P Finley; P E Wakely; K E Fellows
Journal:  Circulation       Date:  1987-03       Impact factor: 29.690

5.  Balloon embolization to occlude a Blalock-Taussig shunt.

Authors:  M Florentine; R R Wolfe; R I White
Journal:  J Am Coll Cardiol       Date:  1984-01       Impact factor: 24.094

6.  Catheter closure of congenital cardiac defects.

Authors:  W E Hellenbrand; C E Mullins
Journal:  Cardiol Clin       Date:  1989-05       Impact factor: 2.213

7.  Transcatheter occlusion of the persistently patent ductus arteriosus. Forty-month follow-up and prevalence of residual shunting.

Authors:  M C Hosking; L N Benson; N Musewe; J D Dyck; R M Freedom
Journal:  Circulation       Date:  1991-12       Impact factor: 29.690

  7 in total
  1 in total

1.  Total UK multi-centre experience with a novel arterial occlusion device (Duct Occlud pfm).

Authors:  A Tometzki; K Chan; J De Giovanni; A Houston; R Martin; D Redel; A Redington; M Rigby; J Wright; N Wilson
Journal:  Heart       Date:  1996-12       Impact factor: 5.994

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.