Literature DB >> 8454247

[The digital reprocessing of under- and overexposed x-ray films with a personal computer].

R Fuhrmann1, P Diedrich.   

Abstract

An image processing work station for digitalizing and interactively manipulating under- and overexposed X-rays was set up by adding modules to an IBM compatible personal computer. Overexposed X-rays can be qualitatively enhanced by means of controlled manipulation of contrast and brightness and by means of the use of various digital filtering techniques. With underexposed X-rays an equalized grey scale can be achieved by means of regulating contrast and brightness. Digital filtering is not required. To assure a high degree of anatomical detail (periodontal ligament) in the digitalized image a maximum pixel of 0.1 mm was defined as a qualitative norm. Since in every digitalization process resolution is diminished, it proved best to select for interactive manipulation out of the total image only the section of interest.

Entities:  

Mesh:

Year:  1993        PMID: 8454247     DOI: 10.1007/bf02168018

Source DB:  PubMed          Journal:  Fortschr Kieferorthop        ISSN: 0015-816X


  13 in total

1.  [The role of x-ray films in diagnosis in operative dentistry].

Authors:  E Sonnabend
Journal:  Dtsch Zahnarztl Z       Date:  1990-11

2.  [Digital image processing in endodontics].

Authors:  M Hulsmann; A Jager; N Steinhofel
Journal:  Dtsch Zahnarztl Z       Date:  1990-07

3.  [Evaluation of the new radiovisiography system].

Authors:  C Benz; P Schwarz; E Sonnabend
Journal:  Dtsch Zahnarztl Z       Date:  1990-11

4.  [RadioVisioGraphie--system for film-free intraoral radiographs].

Authors:  C Benz; F Mouyen
Journal:  Dtsch Zahnarztl Z       Date:  1989-03

5.  Computerized densitometric analysis of interproximal bone levels in a controlled clinical study into the treatment of periodontal bone defects with ceramic hydroxyapatite implant material.

Authors:  P N Galgut; J Verrier; I M Waite; A Linney; D E Cornick
Journal:  J Periodontol       Date:  1991-01       Impact factor: 6.993

6.  A microcomputer system for the analysis of dental radiographs.

Authors:  J Verrier; I Waite; A Linney; D Sutton; P Galgut
Journal:  Br Dent J       Date:  1989-08-19       Impact factor: 1.626

7.  Effect of image enhancement for detectability of bone lesions in digitized intraoral radiographs.

Authors:  A Wenzel
Journal:  Scand J Dent Res       Date:  1988-04

8.  Effect of varying gray-scale resolution for detectability of bone lesions in intraoral radiographs digitized for teletransmission.

Authors:  A Wenzel
Journal:  Scand J Dent Res       Date:  1987-12

9.  Digital radiography of subtle pulmonary abnormalities: an ROC study of the effect of pixel size on observer performance.

Authors:  H MacMahon; C J Vyborny; C E Metz; K Doi; V Sabeti; S L Solomon
Journal:  Radiology       Date:  1986-01       Impact factor: 11.105

10.  [The enhancement of profile and skull radiographic images using the logetronic contrast adjustment method].

Authors:  C W Schwarze
Journal:  Fortschr Kieferorthop       Date:  1983-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.