Literature DB >> 8450729

Evaluation of moment-angle curves in isokinetic knee extension.

M F Bobbert1, J Harlaar.   

Abstract

The purpose of this study was to challenge the notion that the relationship of moment of force to angular velocity, determined in isokinetic knee extension tests, reflects the force-velocity relationship of human knee extensors. For this purpose, maximum-effort isometric knee extension moments were collected at seven different knee joint angles, and maximum-effort isokinetic knee extension moments were measured as a function of knee joint angle at angular velocities of 30, 60, 120, and 210 degrees.s-1. For the isokinetic contractions two protocols were used with a different threshold moment, i.e., the minimum knee extension moment that had to be reached isometrically before knee extension was initiated. In one protocol (LTM, for low threshold moment) the threshold was set at 5% of the maximum isometric knee extension moment produced at the starting angle of 85 degrees (180 degrees being full knee extension), in the second protocol (HTM, for high threshold moment) it was set at 95% of this isometric moment. During all contractions, electromyograms were recorded from m. vastus medialis, m. vastus lateralis, m. rectus femoris, and m. biceps femoris. The EMG signals were rectified and smoothed to yield SREMG. Two hypotheses were specifically tested. The first was that the threshold moment does not affect knee extension moments in the middle of the range of motion. Between knee angles of 100 degrees and 145 degrees, no differences were found between moments produced in the HTM protocol and those produced in the LTM protocol. Thus, the first hypothesis was supported. The second hypothesis was that subjects achieve the same level of muscle excitation at different speeds.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1993        PMID: 8450729

Source DB:  PubMed          Journal:  Med Sci Sports Exerc        ISSN: 0195-9131            Impact factor:   5.411


  5 in total

1.  Effects of pretension on work and power output of the muscle-tendon complex in dynamic elbow flexion.

Authors:  Akinobu Wakayama; Akinori Nagano; Dean Hay; Senshi Fukashiro
Journal:  Eur J Appl Physiol       Date:  2005-01-14       Impact factor: 3.078

Review 2.  Quantification of quadriceps and hamstring antagonist activity.

Authors:  E Kellis
Journal:  Sports Med       Date:  1998-01       Impact factor: 11.136

3.  Computer-assisted hand-held dynamometer: low-cost instrument for muscle function assessment in rehabilitation medicine.

Authors:  J Harlaar; M E Roebroeck; G J Lankhorst
Journal:  Med Biol Eng Comput       Date:  1996-09       Impact factor: 2.602

4.  Antagonist moment of force during maximal knee extension in pubertal boys: effects of quadriceps fatigue.

Authors:  Eleftherios Kellis
Journal:  Eur J Appl Physiol       Date:  2003-03-04       Impact factor: 3.078

5.  The effects of elbow joint angle change on the elbow flexor muscle activation in pulley with weight exercise.

Authors:  Taewook Kang; Youngjoon Seo; Jaehoon Park; Eunseok Dong; Byungdo Seo; Dongwook Han
Journal:  J Phys Ther Sci       Date:  2013-10-20
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.