Literature DB >> 8449049

Emergency department treatment of severe asthma. Metered-dose inhaler plus holding chamber is equivalent in effectiveness to nebulizer.

A H Idris1, M F McDermott, J C Raucci, A Morrabel, S McGorray, L Hendeles.   

Abstract

STUDY
OBJECTIVE: To compare the effectiveness of administration of albuterol by nebulizer or by a metered-dose inhaler having a holding chamber attachment (hereafter "inhaler") for treatment of acute asthma in an emergency department (ED).
DESIGN: A randomized, double-blind, placebo-controlled intervention study conducted at two sites.
SETTING: The EDs of a large municipal hospital and a university teaching hospital. PATIENTS: Thirty-five patients 10 to 45 years of age seeking treatment at an ED for acute asthma.
INTERVENTIONS: Patients were randomly assigned to receive either albuterol by nebulizer plus placebo by inhaler (n = 20) or albuterol by inhaler plus placebo by nebulizer (n = 15). The dose was repeated every 30 min until the FEV1 was at least 80 percent of predicted, the patient became asymptomatic, or 6 doses had been given. MEASUREMENTS AND
RESULTS: All references in this article to spirometric measurements of forced expiratory volume in 1 s (FEV1), forced vital capacity (FVC), and peak expiratory flow rate (PEFR) represent percentages of the predicted normal value. No significant (p > 0.58) differences occurred in baseline mean FEV1, FVC, or PEFR for the two groups. For both groups, significant improvement occurred in mean FEV1 at 30 min (p < 0.02) and at 60 min (p < 0.02), and in maximum mean FEV1 (p < 0.001). However, no significant (p > 0.6) differences occurred between groups in mean FEV1, FVC, or PEFR at 30 and 60 min, or in maximum improvement attained. The sample size was sufficiently large to detect a 12 percent difference in improvement with a power of 90 percent. Thirty-three of 35 patients were treated successfully with the study protocol, became asymptomatic, and were discharged home. One patient from each group required further treatment.
CONCLUSIONS: There was no detectable difference in effectiveness of albuterol administered by nebulizer or the inhaler system for treatment of acute asthma. There was no detectable difference in effectiveness of albuterol administered by nebulizer or the inhaler system for the treatment of acute asthma when the dose was titrated to clinical response. When compared with nebulizer, the metered-dose inhaler with holding chamber delivers a full dose of albuterol more quickly and at no higher cost.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8449049     DOI: 10.1378/chest.103.3.665

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  25 in total

Review 1.  Severe acute asthma.

Authors:  S Salmeron; M Bard; F X Blanc; A Ellrodt
Journal:  Clin Rev Allergy Immunol       Date:  1999       Impact factor: 8.667

Review 2.  Pharmacologic management of the hospitalized pediatric asthma patient.

Authors:  K A Hardin; H J Kallas; R J McDonald
Journal:  Clin Rev Allergy Immunol       Date:  2001-06       Impact factor: 8.667

Review 3.  Status asthmaticus. From the emergency department to the intensive care unit.

Authors:  N Kenyon; T E Albertson
Journal:  Clin Rev Allergy Immunol       Date:  2001-06       Impact factor: 8.667

4.  Relative bioavailability of salbutamol to the lung following inhalation when administration is prolonged.

Authors:  V L Silkstone; H S Tomlinson; S A Corlett; H Chrystyn
Journal:  Br J Clin Pharmacol       Date:  2000-09       Impact factor: 4.335

Review 5.  Asthma exacerbations. 5: assessment and management of severe asthma in adults in hospital.

Authors:  Sarah Aldington; Richard Beasley
Journal:  Thorax       Date:  2007-05       Impact factor: 9.139

Review 6.  Management of acute asthma in adults in the emergency department: nonventilatory management.

Authors:  Rick Hodder; M Diane Lougheed; Brian H Rowe; J Mark FitzGerald; Alan G Kaplan; R Andrew McIvor
Journal:  CMAJ       Date:  2009-10-26       Impact factor: 8.262

7.  Lung delivery of non-CFC salbutamol via small volume metal spacer and large volume plastic spacer devices compared with an open vent jet nebulizer.

Authors:  B J Lipworth; D J Clark
Journal:  Br J Clin Pharmacol       Date:  1998-02       Impact factor: 4.335

8.  Choose better device to treat asthma and put on a happy face.

Authors:  M T Newhouse
Journal:  CMAJ       Date:  1996-08-15       Impact factor: 8.262

9.  Guidance on the diagnosis and management of asthma among adults in resource limited settings.

Authors:  Bruce J Kirenga; Jeremy I Schwartz; Corina de Jong; Thys van der Molen; Martin Okot-Nwang
Journal:  Afr Health Sci       Date:  2015-12       Impact factor: 0.927

10.  Relationship between recent short-acting beta-agonist use and subsequent asthma exacerbations.

Authors:  Jason Paris; Edward L Peterson; Karen Wells; Manel Pladevall; Esteban G Burchard; Shweta Choudhry; David E Lanfear; L Keoki Williams
Journal:  Ann Allergy Asthma Immunol       Date:  2008-11       Impact factor: 6.347

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.