Literature DB >> 8441028

Influence of dose selection on absorbed dose profiles in radioiodine treatment of diffuse toxic goiters in patients receiving or not receiving carbimazole.

J Clerc1, M Izembart, F Dagousset, J P Jaïs, H M Heshmati, A Chevalier, A F Léger, L Barritault.   

Abstract

We retrospectively reviewed the records of 224 patients with diffuse goiters treated with radioiodine, half of which received carbimazole. In all the cases, we carefully monitored the calculation of dosage. A lower percentage of early hypothyroidism but a higher failure rate was observed in the carbimazole subgroup. Nevertheless, after one year, a constant (4.5%) incremental rate of hypothyroidism was found regardless of carbimazole administration. Since we were able to precisely estimate the absorbed doses in our series, we evaluated by simulation the dosimetric profiles of nine methods of dose selection (MDS). These MDS were calibrated in such a way that the same threshold value of absorbed dose would always be reached at the thyroid level. We showed that the more elaborate the MDS, the more accurate the irradiation at the thyroid level and the lower the radiation dose administered. In patients not receiving carbimazole, a rapid MDS using modified early uptake measurements to predict the 24-hr actual value was found to be advisable. With patients receiving carbimazole and if a goal is to delay the occurrence of hypothyroidism, we advise MDS based on either a 48-hr uptake or on the calculation of the individual half-life.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8441028

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  4 in total

1.  Outcome of radioiodine therapy without, on or 3 days off carbimazole: a prospective interventional three-group comparison.

Authors:  Martin A Walter; Mirjam Christ-Crain; Christian Schindler; Jan Müller-Brand; Beat Müller
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-04-11       Impact factor: 9.236

2.  Lesion-Wise Comparison of Pre-Therapy and Post-Therapy Effective Half-Life of Iodine-131 in Pediatric and Young Adult Patients with Differentiated Thyroid Cancer Undergoing Radioiodine Therapy.

Authors:  Praveen Kumar; Chandrasekhar Bal; Nishikant Avinash Damle; Sanjana Ballal; S N Dwivedi; Sandeep Agarwala
Journal:  Nucl Med Mol Imaging       Date:  2019-04-23

3.  Is There Any Need for Adjusting 131I Activity for the Treatment of High Turnover Graves' Disease Compared to Normal Turnover Patients? Results from a Retrospective Cohort Study Validated by Propensity Score Analysis.

Authors:  Saurabh Arora; Chandrasekhar Bal
Journal:  Nucl Med Mol Imaging       Date:  2021-01-07

4.  A mathematical model of optimized radioiodine-131 therapy of Graves' hyperthyroidism.

Authors:  Suhail AR Doi; Issa Loutfi; Kamal AS Al-Shoumer
Journal:  BMC Nucl Med       Date:  2001
  4 in total