Literature DB >> 8433160

Intraoperative localization using an armless, frameless stereotactic wand. Technical note.

G H Barnett1, D W Kormos, C P Steiner, J Weisenberger.   

Abstract

A technique of "frameless" stereotaxy that allows real-time intraoperative neurosurgical localization is described. The system is composed of four components: a hand-held probe containing two ultrasonic emitters, a microphone array that is rigidly affixed to the operating table in proximity to the surgical field, hardware to control and detect timing of signal production and reception, and a color graphics computer workstation with software to calculate and present the location of the probe tip on reconstructed neuroimaging studies. Unlike previously reported mechanical or sonic navigational devices, this system is adaptable to a wide array of neurosurgical instruments, allows free movement of the operating table and conventional patient draping, and has accuracy in the hostile operating room environment that rivals that of frame stereotaxy. In the operating room environment, using four pulse pairs with the wand positioned optimally, reproducibility of a point in space is +/- 0.6 mm. The wand has a broad range of orientations that maintain error at or below 1.0 mm. The mean error when measuring distances within a 1000-cu cm cube is 1.1 +/- 1.0 mm (1.0% +/- 0.7%). The ability to localize a fourth point (a target) in space is typically within 1.5 mm (using computerized tomography scans with a 1-mm slice thickness) but is dependent on several variables. This technology provides a powerful yet flexible tool in the neurosurgical operating room.

Entities:  

Mesh:

Year:  1993        PMID: 8433160     DOI: 10.3171/jns.1993.78.3.0510

Source DB:  PubMed          Journal:  J Neurosurg        ISSN: 0022-3085            Impact factor:   5.115


  13 in total

Review 1.  The role of image-guided technology in the surgical planning and resection of gliomas.

Authors:  G H Barnett
Journal:  J Neurooncol       Date:  1999-05       Impact factor: 4.130

Review 2.  Computer-aided navigation in neurosurgery.

Authors:  P Grunert; K Darabi; J Espinosa; R Filippi
Journal:  Neurosurg Rev       Date:  2003-05       Impact factor: 3.042

Review 3.  Stereotactic technology in tumor surgery: concepts and principles.

Authors:  D W Roberts
Journal:  J Neurooncol       Date:  1995       Impact factor: 4.130

Review 4.  Intraoperative assistive technologies and extent of resection in glioma surgery: a systematic review of prospective controlled studies.

Authors:  Breno José Alencar Pires Barbosa; Eric Domingos Mariano; Chary Marquez Batista; Suely Kazue Nagahashi Marie; Manoel Jacobsen Teixeira; Carlos Umberto Pereira; Marcos Soares Tatagiba; Guilherme Alves Lepski
Journal:  Neurosurg Rev       Date:  2014-12-04       Impact factor: 3.042

5.  Integration of the OpenIGTLink network protocol for image-guided therapy with the medical platform MeVisLab.

Authors:  Jan Egger; Junichi Tokuda; Laurent Chauvin; Bernd Freisleben; Christopher Nimsky; Tina Kapur; William Wells
Journal:  Int J Med Robot       Date:  2012-02-28       Impact factor: 2.547

Review 6.  Neuronavigation and surgery of intracerebral tumours.

Authors:  P W A Willems; J W Berkelbach van der Sprenkel; C A F Tulleken; M A Viergever; M J B Taphoorn
Journal:  J Neurol       Date:  2006-09-20       Impact factor: 4.849

7.  OpenIGTLink: an open network protocol for image-guided therapy environment.

Authors:  Junichi Tokuda; Gregory S Fischer; Xenophon Papademetris; Ziv Yaniv; Luis Ibanez; Patrick Cheng; Haiying Liu; Jack Blevins; Jumpei Arata; Alexandra J Golby; Tina Kapur; Steve Pieper; Everette C Burdette; Gabor Fichtinger; Clare M Tempany; Nobuhiko Hata
Journal:  Int J Med Robot       Date:  2009-12       Impact factor: 2.547

8.  Stereotactic navigation for TAMIS-TME: opening the gateway to frameless, image-guided abdominal and pelvic surgery.

Authors:  Sam Atallah; George Nassif; Sergio Larach
Journal:  Surg Endosc       Date:  2014-06-28       Impact factor: 4.584

9.  Neuronavigation: principles, clinical applications and potential pitfalls.

Authors:  Alireza Khoshnevisan; Narges Sistany Allahabadi
Journal:  Iran J Psychiatry       Date:  2012

10.  High-sensitivity acoustic sensors from nanofibre webs.

Authors:  Chenhong Lang; Jian Fang; Hao Shao; Xin Ding; Tong Lin
Journal:  Nat Commun       Date:  2016-03-23       Impact factor: 14.919

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.