Literature DB >> 843135

Respiratory characteristics of a microporous membrane oxygenator.

K E Karlson, R J Massimino, G N Cooper, A K Singh, L L Vargas.   

Abstract

A microporous membrane oxygenator has been used in 258 clinical perfusions for cardiac surgery. In 132 perfusions the oxygenator was ventilated with 100% O2, and in 126 perfusions 98% O2-2%CO2 was used. Patients' BSA was 0.4-2.3 M2. Bypass duration was up to 563 min. In the group ventilated with 100% O2, average PaCO2 was 30 mmHg, with arterial pH of 7.48. 98% O2-2% ventilation resulted in an average PaCO2 of 36 mmHg, with arterial pH of 7.41. CO2 transfer is influenced by gas flow rate, and data from selected cases demonstrate that increasing gas flow results in decreasing PaCO2, while decreasing gas flow increases PaCO2. The thickness of the blood film is decreased by increasing the "shim" pressure, so that increasing the "shim" presure results in higher PaO2. Oxygen saturation averaged 99% for the entire series. Addition of CO2 to the oxygen and appropriate changes in gas flow and "shim" pressure permit changes to be made in the ventilation of the device during perfusion to achieve desired levels of PaO2 and PaCO2 under widely disparate conditions of temperature and flow.

Entities:  

Mesh:

Substances:

Year:  1977        PMID: 843135      PMCID: PMC1396144          DOI: 10.1097/00000658-197704000-00004

Source DB:  PubMed          Journal:  Ann Surg        ISSN: 0003-4932            Impact factor:   12.969


  6 in total

1.  Clinical experience with the Teflo disposable membrane oxygenator.

Authors:  A C Beall; R T Solis; M Kakvan; G C Morris; G P Noon; M E DeBakey
Journal:  Ann Thorac Surg       Date:  1976-02       Impact factor: 4.330

2.  Hematologic responses to prolonged extracorporeal circulation (ECC) with microporous membrane devices.

Authors:  R H Bartlett; S W Fong; C Woldanski; E Hung; D Styler; C MacArthur
Journal:  Trans Am Soc Artif Intern Organs       Date:  1975

3.  Comparison of the effects of membrane and non-membrane oxygenators on the biochemical and biophysical characteristics of blood.

Authors:  W H LEE; D KRUMHAAR; G DERRY; D SACHS; S H LAWRENCE; G H CLOWES; J V MALONEY
Journal:  Surg Forum       Date:  1961

4.  Cardiopulmonary bypass. Microembolization and platelet aggregation.

Authors:  R T Solis; P S Kennedy; A C Beall; G P Noon; M E DeBakey
Journal:  Circulation       Date:  1975-07       Impact factor: 29.690

5.  Total cardiopulmonary bypass with a new microporous Teflon membrane oxygenator.

Authors:  K E Karlson; W R Murphy; M Kakvan; P Anthony; G N Cooper; P D Richardson; P M Galletti
Journal:  Surgery       Date:  1974-12       Impact factor: 3.982

6.  Membrane vs bubble oxygenator: clinical comparison.

Authors:  J E Liddicoat; S M Bekassy; A C Beall; D H Glaeser; M E DeBakey
Journal:  Ann Surg       Date:  1975-05       Impact factor: 12.969

  6 in total
  1 in total

1.  Laboratory and clinical evaluation of a membrane oxygenator with secondary flows in the blood channels.

Authors:  K E Karlson; R J Massimino; A K Singh; G N Cooper
Journal:  World J Surg       Date:  1982-05       Impact factor: 3.352

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.