Literature DB >> 8430343

Ultrasound examination for measurement of femoral anteversion in children.

T Terjesen1, S Anda, H Rønningen.   

Abstract

Femoral anteversion (AV) angles were determined by ultrasound and biplanar radiography in 63 children aged 3-11 years. With the patient supine, knees flexed 90 degrees, and legs kept vertical, only one ultrasound scan of the proximal femur was needed. The anterior tangent of the femoral head and the greater trochanter was used as the reference line. The transducer was tilted until this tangent appeared horizontal on the monitor screen, and the angle of tilt, which represents the AV angle, was measured with an attached clinometer. There was a high correlation between ultrasound and radiographic results (r = 0.71). However, the AV angles appeared an average of 5.5 degrees larger by ultrasound. Thus, a correction factor of 5 degrees should be subtracted from the angle measured by ultrasound to obtain the actual AV angle in children. Because ultrasound does not require ionizing radiation, and because reliable results are obtained, our technique is recommended for screening of children with rotational disorders of the femur.

Entities:  

Mesh:

Year:  1993        PMID: 8430343     DOI: 10.1007/bf00191522

Source DB:  PubMed          Journal:  Skeletal Radiol        ISSN: 0364-2348            Impact factor:   2.199


  13 in total

1.  [Determination of the antetorsion of the femur neck by means of two x-ray pictures].

Authors:  J RIPPSTEIN
Journal:  Z Orthop Ihre Grenzgeb       Date:  1955

2.  Femoral anteversion measured by ultrasonography and radiography. An anatomic investigation.

Authors:  S Anda; T Terjesen; S Sundalsfoll; A Tangerud
Journal:  Acta Radiol       Date:  1988 Nov-Dec       Impact factor: 1.990

3.  Measurement of femoral torsion: comparison of standard roentgenographic techniques with ultrasound.

Authors:  H O Phillips; W B Greene; W B Guilford; C A Mittelstaedt; G Gaisie; L M Vincent; C Durell
Journal:  J Pediatr Orthop       Date:  1985 Sep-Oct       Impact factor: 2.324

4.  [Measurement of antetorsion of the femoral neck by ultrasonics. Comparison with x-ray computed tomography].

Authors:  J P Clarac; P Pries; M Laine; J P Richer; H Freychet; F Goubault; D Barret; A Hurmic; P Vandermarcq; J Drouineau
Journal:  Rev Chir Orthop Reparatrice Appar Mot       Date:  1985

5.  Femoral anteversion in children measured by ultrasound.

Authors:  T Terjesen; S Anda
Journal:  Acta Orthop Scand       Date:  1987-08

6.  Anteversion of the femoral neck.

Authors:  L Ruby; M A Mital; J O'Connor; U Patel
Journal:  J Bone Joint Surg Am       Date:  1979-01       Impact factor: 5.284

7.  [Determination of femur neck anteversion by echography].

Authors:  R Zarate; C Cuny; P Sazos
Journal:  J Radiol       Date:  1983-05

8.  Regression of femoral anteversion. A prospective study of intoeing children.

Authors:  S Svenningsen; K Apalset; T Terjesen; S Anda
Journal:  Acta Orthop Scand       Date:  1989-04

9.  Growth alterations in the hemiplegic child. A study of femoral anteversion, neck-shaft angle, hip rotation, C.E. angle, limb length and circumference in 50 hemiplegic children.

Authors:  L T Staheli; W R Duncan; E Schaefer
Journal:  Clin Orthop Relat Res       Date:  1968 Sep-Oct       Impact factor: 4.176

10.  Femoral anteversion in normal adults. Ultrasound measurements in 50 men and 50 women.

Authors:  M Bråten; T Terjesen; I Rossvoll
Journal:  Acta Orthop Scand       Date:  1992-02
View more
  1 in total

Review 1.  Femoral anteversion: significance and measurement.

Authors:  Matteo Scorcelletti; Neil D Reeves; Jörn Rittweger; Alex Ireland
Journal:  J Anat       Date:  2020-06-24       Impact factor: 2.610

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.