Literature DB >> 8430006

Review of the tear break-up time and a closer look at the tear break-up time of Hong Kong Chinese.

P Cho1, B Brown.   

Abstract

The technique of assessing tear stability using the fluorescein instillation technique has been widely used in the clinical diagnosis of "dry eye" and in the screening of potential contact lens wearers. Various inconsistencies in the application of the tear break-up time (TBUT) techniques and the results obtained were noted in the literature and this review summarizes the differences and the conclusions of various investigators. The reliability of this technique using two different methods of observation was examined and the mean TBUT of Hong Kong Chinese subjects (HK-Chinese) was determined. We conclude that the TBUT can be measured reliably using either the scanning or full beam method in most patients. The mean TBUT of HK-Chinese is approximately 8 s and about 70% of HK-Chinese have TBUT's less than 10 s.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8430006     DOI: 10.1097/00006324-199301000-00007

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  7 in total

1.  Agreement between Automated and Traditional Measures of Tear Film Breakup.

Authors:  Stephanie M Cox; Kelly K Nichols; Jason J Nichols
Journal:  Optom Vis Sci       Date:  2015-09       Impact factor: 1.973

2.  Comparison of Dry Eye Parameters between Diabetics and Non-Diabetics in District of Kuantan, Pahang.

Authors:  Mohammed Aljarousha; Noor Ezailina Badarudin; Mohd Zulfaezal Che Azemin
Journal:  Malays J Med Sci       Date:  2016-05

Review 3.  Mechanisms, imaging and structure of tear film breakup.

Authors:  P Ewen King-Smith; Carolyn G Begley; Richard J Braun
Journal:  Ocul Surf       Date:  2017-09-20       Impact factor: 5.033

4.  Blue-yellow colour vision in an onchocercal area of northern Nigeria.

Authors:  A Landers; I E Murdoch; J Birch; S N Cousens; O E Babalola; B Lawal; A Abiose; B R Jones
Journal:  Br J Ophthalmol       Date:  1998-05       Impact factor: 4.638

5.  Pre-corneal tear film thickness in humans measured with a novel technique.

Authors:  Kaveh Azartash; Justin Kwan; Jerry R Paugh; Andrew Loc Nguyen; James V Jester; Enrico Gratton
Journal:  Mol Vis       Date:  2011-03-22       Impact factor: 2.367

6.  Efficacy of the Fluorescein Tear Breakup Time Test in Dry Eye.

Authors:  Jerry R Paugh; June Tse; Tiffany Nguyen; Alan Sasai; Elaine Chen; Melinda Thomas De Jesus; Justin Kwan; Andrew Loc Nguyen; Marjan Farid; Sumit Garg; James V Jester
Journal:  Cornea       Date:  2020-01       Impact factor: 3.152

7.  Ocular surface cooling rate associated with tear film characteristics and the maximum interblink period.

Authors:  Jennifer E Ding; Young Hyun Kim; Sarah M Yi; Andrew D Graham; Wing Li; Meng C Lin
Journal:  Sci Rep       Date:  2021-07-22       Impact factor: 4.379

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.