Literature DB >> 8429796

Endogenous susceptibility contrast in myocardium during apnea measured using gradient recalled echo planar imaging.

M F Wendland1, M Saeed, K Lauerma, A de Crespigny, M E Moseley, C B Higgins.   

Abstract

Gradient recalled echo planar imaging was used to monitor changes in myocardial and left ventricular chamber blood intensity during apnea in rats. Significant signal loss in both blood (to 62 +/- 5% and 51 +/- 6% of baseline) and myocardium (to 79 +/- 2% and 76 +/- 3% of baseline) was observed at 45 and 90 s apnea while O2 saturation decreased from 98 +/- 1% to 62 +/- 7% and 36 +/- 9%, respectively. These results show that myocardial intensity is modulated by alterations in blood oxygenation.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8429796     DOI: 10.1002/mrm.1910290220

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  8 in total

1.  In vivo measurement of T*2 and field inhomogeneity maps in the human heart at 1.5 T.

Authors:  S B Reeder; A Z Faranesh; J L Boxerman; E R McVeigh
Journal:  Magn Reson Med       Date:  1998-06       Impact factor: 4.668

2.  Quantitative cardiac perfusion: a noninvasive spin-labeling method that exploits coronary vessel geometry.

Authors:  S B Reeder; M K Atalay; E R McVeigh; E A Zerhouni; J R Forder
Journal:  Radiology       Date:  1996-07       Impact factor: 11.105

3.  Simultaneous noninvasive determination of regional myocardial perfusion and oxygen content in rabbits: toward direct measurement of myocardial oxygen consumption at MR imaging.

Authors:  S B Reeder; A A Holmes; E R McVeigh; J R Forder
Journal:  Radiology       Date:  1999-09       Impact factor: 11.105

Review 4.  The Potential of Oxygenation-Sensitive CMR in Heart Failure.

Authors:  Elizabeth Hillier; Matthias G Friedrich
Journal:  Curr Heart Fail Rep       Date:  2021-08-11

5.  Myocardial Tissue Oxygenation and Microvascular Blood Volume Measurement Using a Contrast Blood Oxygenation Level-Dependent Imaging Model.

Authors:  Jeffrey M Dendy; Sean G Hughes; Jonathan H Soslow; Daniel E Clark; Cynthia B Paschal; John C Gore
Journal:  Invest Radiol       Date:  2022-04-13       Impact factor: 10.065

6.  Oxygenation-sensitive CMR for assessing vasodilator-induced changes of myocardial oxygenation.

Authors:  Matthias Vöhringer; Jacqueline A Flewitt; Jordin D Green; Rohan Dharmakumar; Jiun Wang; John V Tyberg; Matthias G Friedrich
Journal:  J Cardiovasc Magn Reson       Date:  2010-03-31       Impact factor: 5.364

Review 7.  Blood oxygenation level dependent functional magnetic resonance imaging: current and potential uses in obstetrics and gynaecology.

Authors:  K Vincent; J Moore; S Kennedy; I Tracey
Journal:  BJOG       Date:  2009-01       Impact factor: 6.531

Review 8.  Oxygenation-sensitive cardiovascular magnetic resonance.

Authors:  Matthias G Friedrich; Theodoros D Karamitsos
Journal:  J Cardiovasc Magn Reson       Date:  2013-05-24       Impact factor: 5.364

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.