Literature DB >> 8429337

Noninvasive, real-time monitoring of renal function: the ambulatory renal monitor.

C A Rabito1, R H Moore, C Bougas, S C Dragotakes.   

Abstract

The objective of this study was to develop a method for the noninvasive, continuous and real-time monitoring of renal function. A radiation detector attached to a miniature data logger was used to monitor the clearance of the glomerular filtration agent 99mTc-diethylenetriaminepentaacetic acid from the extracellular space. The rate constant (k) for this clearance showed an excellent correlation with simultaneous glomerular filtration rate (GFR) measurements performed with a standard 125I-iothalamate clearance technique in 50 patients. Moreover, the reproducibility of the k measurement for an individual or a population was superior to the GFR measurement performed with the standard clearance technique. The procedure was also used to monitor the renal function in patients at risk for acute renal failure during angiography or in the intensive care unit under noninvasive and near real-time conditions. The results show that the technique detects rapid changes in renal function with a resolution time of 5 min in patients with normal renal function and 15 min in patients with severely impaired renal function. Since the method is noninvasive, precise and provides a near real-time measurement of GFR, its use may lead to an improvement in the management of patients in situations in which a rapid measurement is the major concern.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8429337

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  6 in total

1.  A portable fiberoptic ratiometric fluorescence analyzer provides rapid point-of-care determination of glomerular filtration rate in large animals.

Authors:  Exing Wang; Daniel J Meier; Ruben M Sandoval; Vanessa E Von Hendy-Willson; Barrak M Pressler; Robert M Bunch; Mouhamad Alloosh; Michael S Sturek; George J Schwartz; Bruce A Molitoris
Journal:  Kidney Int       Date:  2011-08-31       Impact factor: 10.612

2.  Determination of renal function and injury using near-infrared fluorimetry in experimental cardiorenal syndrome.

Authors:  Mizuko Ikeda; Rumie Wakasaki; Katie J Schenning; Thomas Swide; Jeong Heon Lee; M Bernie Miller; Hak Soo Choi; Sharon Anderson; Michael P Hutchens
Journal:  Am J Physiol Renal Physiol       Date:  2017-01-11

3.  Rapid diagnosis and quantification of acute kidney injury using fluorescent ratio-metric determination of glomerular filtration rate in the rat.

Authors:  Exing Wang; Ruben M Sandoval; Silvia B Campos; Bruce A Molitoris
Journal:  Am J Physiol Renal Physiol       Date:  2010-08-04

Review 4.  Quantifying Glomerular Filtration Rates in Acute Kidney Injury: A Requirement for Translational Success.

Authors:  Bruce A Molitoris; Erinn S Reilly
Journal:  Semin Nephrol       Date:  2016-01       Impact factor: 5.299

5.  Glomerular filtration rate in relation to extracellular fluid volume: similarity between 99mTc-DTPA and inulin.

Authors:  R D Gunasekera; D J Allison; A M Peters
Journal:  Eur J Nucl Med       Date:  1996-01

6.  Transcutaneous renal function monitor: precision during unsteady hemodynamics.

Authors:  L A Bauman; N E Watson; P E Scuderi; M A Peters
Journal:  J Clin Monit Comput       Date:  1998-05       Impact factor: 2.502

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.