Unreliability of blood pressure and heart rate to evaluate cardiac output in emergency resuscitation and critical illness.

C C Wo1, W C Shoemaker, P L Appel, M H Bishop, H B Kram, E Hardin.   

Abstract

OBJECTIVE: To evaluate the reliability of the vital signs to evaluate circulatory stability as reflected by cardiac index.
DESIGN: Descriptive analysis based on data gathered prospectively, using a predetermined protocol.
SETTING: University-run county hospital, with a large trauma service. PATIENTS: Sixty-one high-risk trauma patients with accidental injury who were studied immediately after admission to the Emergency Department, and subsequently, 163 critically ill postoperative ICU patients.
INTERVENTIONS: Standard fluid therapy, usually crystalloids, but occasionally packed red cell transfusions and colloids, as indicated by clinical criteria. MEASUREMENTS AND
RESULTS: Arterial BP was measured by pressure transducer and arterial catheter; heart rate (HR) was measured by electrocardiograph signal, and cardiac output was measured by thermodilution. In sudden severe hypovolemic hypotension, the mean arterial pressure (MAP) nadir (lowest) roughly correlated (r2 = .25) with flow, but there was poor correlation (r2 = .0001) when all pressure and flow values were evaluated. The pressure and flow values were obtained throughout the course of the hypotensive episodes during the initial resuscitation in ICU patients and during terminal illnesses.
CONCLUSIONS: Observations at the time of acute severe hypotensive crises that show rough correlation of MAP and cardiac index should not be extrapolated throughout the entire hypotensive period or to other less extreme clinical situations. The stress response to hypovolemia, with endogenous catecholamines and neural mechanisms, tends to maintain arterial pressure in the face of decreasing flow for a variable period of time. However, when these mechanisms are overwhelmed by prolonged hypovolemia, the pressure decreases precipitously, but not synchronously, with flow. We conclude that blood flow cannot reliably be inferred from arterial pressure and heart rate measurements until extreme hypotension occurs.

Entities:  

Mesh:

Year:  1993        PMID: 8428472     DOI: 10.1097/00003246-199302000-00012

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  53 in total

1.  The effects of advanced monitoring on hemodynamic management in critically ill patients: a pre and post questionnaire study.

Authors:  Azriel Perel; Bernd Saugel; Jean-Louis Teboul; Manu L N G Malbrain; Francisco Javier Belda; Enrique Fernández-Mondéjar; Mikhail Kirov; Julia Wendon; Roger Lussmann; Marco Maggiorini
Journal:  J Clin Monit Comput       Date:  2015-12-10       Impact factor: 2.502

Review 2.  Early and innovative interventions for severe sepsis and septic shock: taking advantage of a window of opportunity.

Authors:  Emanuel P Rivers; Lauralyn McIntyre; David C Morro; Kandis K Rivers
Journal:  CMAJ       Date:  2005-10-25       Impact factor: 8.262

Review 3.  [Treatment of hemorrhagic shock. New therapy options].

Authors:  W G Voelckel; A von Goedecke; D Fries; A C Krismer; V Wenzel; K H Lindner
Journal:  Anaesthesist       Date:  2004-12       Impact factor: 1.041

4.  Accuracy of the caval index and the expiratory diameter of the inferior vena cava for the diagnosis of dehydration in elderly.

Authors:  Daniele Orso; Nicola Guglielmo; Nicola Federici; Francesco Cugini; Alessio Ban; Filippo Mearelli; Roberto Copetti
Journal:  J Ultrasound       Date:  2016-04-08

5.  Invasive and noninvasive hemodynamic monitoring of patients with cerebrovascular accidents.

Authors:  G C Velmahos; C C Wo; D Demetriades; M H Bishop; W C Shoemaker
Journal:  West J Med       Date:  1998-07

Review 6.  Extended focused assessment with sonography in trauma.

Authors:  N Desai; T Harris
Journal:  BJA Educ       Date:  2017-11-28

7.  Changes in stroke distance in response to haemorrhage in a swine model.

Authors:  M J Clancy; J Alderman; N Cavallero; K J Taylor
Journal:  J Accid Emerg Med       Date:  1996-09

8.  Lactate: prognostic biomarker in severely burned patients.

Authors:  A Mokline; A Abdenneji; I Rahmani; L Gharsallah; S Tlaili; I Harzallah; B Gasri; R Hamouda; A A Messadi
Journal:  Ann Burns Fire Disasters       Date:  2017-03-31

9.  Simultaneous multi-depth assessment of tissue oxygen saturation in thenar and forearm using near-infrared spectroscopy during a simple cardiovascular challenge.

Authors:  Rick Bezemer; John M Karemaker; Eva Klijn; Daniel Martin; Kay Mitchell; Mike Grocott; Michal Heger; Can Ince
Journal:  Crit Care       Date:  2009-11-30       Impact factor: 9.097

Review 10.  The microcirculation as a diagnostic and therapeutic target in sepsis.

Authors:  Andrea Nencioni; Stephen Trzeciak; Nathan I Shapiro
Journal:  Intern Emerg Med       Date:  2009-08-26       Impact factor: 3.397

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.