Literature DB >> 8427111

Constructive interference in steady state-3DFT MR imaging of the inner ear and cerebellopontine angle.

J W Casselman1, R Kuhweide, M Deimling, W Ampe, I Dehaene, L Meeus.   

Abstract

PURPOSE: To assess the value of a three-dimensional Fourier transformation MR technique "CISS" (constructive interference in steady state) in imaging the inner ear.
SUBJECTS: We studied 50 normal inner ears (40 axial, 10 coronal) and 10 pathologic inner ears in 60 patients.
RESULTS: The cochlea, semicircular canals, and vestibulum were visualized in detail. Cranial nerve VII and the cochlear, superior vestibular, and inferior vestibular branch of cranial nerve VIII were identified in 90%, 94%, 80%, and 88% of the cases, respectively. A vascular loop was recognized inside the internal auditory canal in 6%, and in the porus in 30%, of the cases. The high signal of the cerebrospinal fluid and labyrinthine fluids (perilymph and endolymph) on the CISS images made excellent delineation of tumors in the cerebellopontine angle and internal canal possible and allowed detection of tumoral labyrinth involvement. The thin sections, high resolution of the images, and capability of producing multiplanar and three-dimensional reconstructions often offered additional information.
CONCLUSIONS: The CISS sequence allows detailed study of the normal and pathologic inner ear and promises to be highly valuable in the demonstration of the vascular loop.

Entities:  

Mesh:

Year:  1993        PMID: 8427111      PMCID: PMC8334438     

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  83 in total

1.  Improved detection of intraventricular cysticercal cysts with the use of three-dimensional constructive interference in steady state MR sequences.

Authors:  S S Govindappa; J P Narayanan; V M Krishnamoorthy; C H Shastry; A Balasubramaniam; S S Krishna
Journal:  AJNR Am J Neuroradiol       Date:  2000-04       Impact factor: 3.825

2.  Increased conspicuity of intraventricular lesions revealed by three-dimensional constructive interference in steady state sequences.

Authors:  D Yang; Y Korogi; Y Ushio; M Takahashi
Journal:  AJNR Am J Neuroradiol       Date:  2000 Jun-Jul       Impact factor: 3.825

3.  MR cisternography of the cerebellopontine angle: comparison of three-dimensional fast asymmetrical spin-echo and three-dimensional constructive interference in the steady-state sequences.

Authors:  S Naganawa; T Koshikawa; H Fukatsu; T Ishigaki; T Fukuta
Journal:  AJNR Am J Neuroradiol       Date:  2001 Jun-Jul       Impact factor: 3.825

4.  Fast recovery 3D fast spin-echo MR imaging of the inner ear at 3 T.

Authors:  Shinji Naganawa; Tokiko Koshikawa; Hiroshi Fukatsu; Takeo Ishigaki; Ikuo Aoki; Ayako Ninomiya
Journal:  AJNR Am J Neuroradiol       Date:  2002-02       Impact factor: 3.825

5.  Detailed imaging of the normal anatomy and pathologic conditions of the cavernous region at 3 Tesla using a contrast-enhanced MR angiography.

Authors:  Jennifer Linn; Friederike Peters; Nina Lummel; Christoph Schankin; Walter Rachinger; Hartmut Brueckmann; Indra Yousry
Journal:  Neuroradiology       Date:  2011-01-27       Impact factor: 2.804

6.  High-resolution T1-weighted 3D real IR imaging of the temporal bone using triple-dose contrast material.

Authors:  Shinji Naganawa; Tokiko Koshikawa; Tatsuya Nakamura; Hiroshi Fukatsu; Takeo Ishigaki; Ikuo Aoki
Journal:  Eur Radiol       Date:  2003-05-07       Impact factor: 5.315

7.  CSF flow imaging in the management of third ventriculostomy with a reversed fast imaging with steady-state precession sequence.

Authors:  Karl T Hoffmann; Thomas N Lehmann; Clemens Baumann; Roland Felix
Journal:  Eur Radiol       Date:  2002-12-13       Impact factor: 5.315

Review 8.  Imaging of the postoperative middle ear.

Authors:  Marc T Williams; Denis Ayache
Journal:  Eur Radiol       Date:  2004-01-29       Impact factor: 5.315

9.  Evaluation of MR cisternography of the cerebellopontine angle using a balanced fast-field-echo sequence: preliminary findings.

Authors:  Kazuhiro Tsuchiya; Chinatsu Aoki; Junichi Hachiya
Journal:  Eur Radiol       Date:  2003-10-03       Impact factor: 5.315

10.  3-T imaging of the cochlear nerve and labyrinth in cochlear-implant candidates: 3D fast recovery fast spin-echo versus 3D constructive interference in the steady state techniques.

Authors:  John I Lane; Heidi Ward; Robert J Witte; Matt A Bernstein; Colin L W Driscoll
Journal:  AJNR Am J Neuroradiol       Date:  2004-04       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.