Literature DB >> 8426007

Hemodynamic correlates of the third heart sound during the evolution of chronic heart failure.

T Kono1, H Rosman, M Alam, P D Stein, H N Sabbah.   

Abstract

OBJECTIVES: The purpose of this study was to examine the temporal relation between the development of a third heart sound during the course of evolving heart failure and associated hemodynamic abnormalities.
BACKGROUND: Although various theories have been proposed to explain the origin of the third heart sound, the exact origin of this sound remains unknown.
METHODS: Studies were performed in seven dogs in which heart failure was produced by multiple sequential intracoronary micro-embolizations. Hemodynamic studies including ventriculography, pulsed wave Doppler echocardiography and intracardiac phonocardiography were performed at baseline, at the time at third heart sound was first heard and at 6 and 24 weeks after onset of the third heart sound.
RESULTS: All dogs developed a third heart sound at 9 +/- 2 weeks after the initial embolization. The onset of the sound was accompanied by an increase in left ventricular chamber stiffness relative to the baseline value (0.25 +/- 0.03 vs. 0.14 +/- 0.01 mm Hg/ml) (p < 0.05) and mean deceleration of early mitral inflow velocity (1,040 +/- 90 vs. 590 +/- 40 cm/s per s) (p < 0.05).
CONCLUSIONS: These data indicate that the onset of a third heart sound during the course of evolving heart failure occurs coincident with the development of increased left ventricular chamber stiffness and the manifestation of rapid deceleration of early mitral inflow velocity. These findings are consistent with a myocardial vibratory origin of this sound.

Entities:  

Mesh:

Year:  1993        PMID: 8426007     DOI: 10.1016/0735-1097(93)90684-s

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  4 in total

1.  Ranolazine combined with enalapril or metoprolol prevents progressive LV dysfunction and remodeling in dogs with moderate heart failure.

Authors:  Sharad Rastogi; Victor G Sharov; Sudhish Mishra; Ramesh C Gupta; Brent Blackburn; Luiz Belardinelli; William C Stanley; Hani N Sabbah
Journal:  Am J Physiol Heart Circ Physiol       Date:  2008-09-26       Impact factor: 4.733

2.  Detection of the third heart sound using a tailored wavelet approach.

Authors:  P Hult; T Fjällbrant; B Wranne; P Ask
Journal:  Med Biol Eng Comput       Date:  2004-03       Impact factor: 2.602

3.  Haemodynamic monitoring of cardiac status using heart sounds from an implanted cardiac device.

Authors:  Pramodsingh H Thakur; Qi An; Lynne Swanson; Yi Zhang; Roy S Gardner
Journal:  ESC Heart Fail       Date:  2017-07-04

4.  Reintroducing Heart Sounds for Early Detection of Acute Myocardial Ischemia in a Porcine Model - Correlation of Acoustic Cardiography With Gold Standard of Pressure-Volume Analysis.

Authors:  Marco Luciani; Matteo Saccocci; Shingo Kuwata; Nikola Cesarovic; Miriam Lipiski; Patricia Arand; Peter Bauer; Andrea Guidotti; Evelyn Regar; Paul Erne; Michel Zuber; Francesco Maisano
Journal:  Front Physiol       Date:  2019-08-22       Impact factor: 4.566

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.