Literature DB >> 8424568

Intraoperative somatosensory evoked potential monitoring predicts peripheral nerve injury during cardiac surgery.

C Hickey1, L D Gugino, L S Aglio, J B Mark, S L Son, R Maddi.   

Abstract

BACKGROUND: Brachial plexus injury may occur without obvious cause in patients undergoing cardiac surgery. To determine whether such peripheral nerve injury can be predicted intraoperatively, we monitored somatosensory evoked potentials (SEPs) from bilateral median and ulnar nerves in 30 patients undergoing coronary artery bypass surgery.
METHODS: SEPs were analyzed for changes during central venous cannulation and during use of the Favoloro and Canadian self-retaining sternal retractors, events hereto implicated in brachial plexus injury. Brachial plexus injury was evaluated during physical examination in the postoperative period by an individual blinded to results of SEP monitoring.
RESULTS: Central venous cannulation was associated with transient changes in SEPs in four patients (13%). These changes occurred intermittently during insertion of the cannula but completely resolved within 5 min. Postoperative neurologic deficits did not occur in these cases. Use of the Canadian and Favoloro retractors was associated with significant changes in 21 patients (70%). In 16 of these, waveforms reverted toward baseline levels intraoperatively and were not associated with postoperative neurologic deficits. Five patients demonstrated a neurologic deficit postoperatively. In each of these, SEP change associated with use of surgical retractors persisted to the end of surgery compared to the immediate pre-bypass period.
CONCLUSION: Intraoperative upper extremity SEPs may be used to predict peripheral nerve injury occurring during cardiac surgery.

Entities:  

Mesh:

Year:  1993        PMID: 8424568     DOI: 10.1097/00000542-199301000-00006

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  10 in total

Review 1.  Brachial plexus injury as an unusual complication of coronary artery bypass graft surgery.

Authors:  A Y Chong; C E Clarke; W R Dimitri; G Y H Lip
Journal:  Postgrad Med J       Date:  2003-02       Impact factor: 2.401

2.  Transcranial electric motor evoked potential detection of compressional peroneal nerve injury in the lateral decubitus position.

Authors:  Vidya M Bhalodia; Anthony K Sestokas; Patrick R Tomak; Daniel M Schwartz
Journal:  J Clin Monit Comput       Date:  2008-08-15       Impact factor: 2.502

3.  Risk factors for positioning-related somatosensory evoked potential changes in 3946 spinal surgeries.

Authors:  Samyuktha R Melachuri; Jeffrey R Balzer; Manasa K Melachuri; David Ninaci; Katherine Anetakis; Jaspreet Kaur; Donald J Crammond; Parthasarathy D Thirumala
Journal:  J Clin Monit Comput       Date:  2018-05-31       Impact factor: 2.502

Review 4.  Positioning patients for spine surgery: Avoiding uncommon position-related complications.

Authors:  Ihab Kamel; Rodger Barnette
Journal:  World J Orthop       Date:  2014-09-18

5.  Neurophysiological identification of position-induced neurologic injury during anterior cervical spine surgery.

Authors:  Daniel M Schwartz; Anthony K Sestokas; Alan S Hilibrand; Alexander R Vaccaro; Bikash Bose; Mark Li; Todd J Albert
Journal:  J Clin Monit Comput       Date:  2006-09-08       Impact factor: 2.502

6.  Somatosensory evoked potentials are not a sensitive indicator of potential positioning injury in the prone patient.

Authors:  N A Lorenzini; K A Poterack
Journal:  J Clin Monit       Date:  1996-03

7.  Evoked potential monitoring identifies possible neurological injury during positioning for craniotomy.

Authors:  Zirka H Anastasian; Brian Ramnath; Ricardo J Komotar; Jeffrey N Bruce; Michael B Sisti; Edward J Gallo; Ronald G Emerson; Eric J Heyer
Journal:  Anesth Analg       Date:  2009-09       Impact factor: 5.108

Review 8.  Intraoperative neurophysiologic monitoring: basic principles and recent update.

Authors:  Sung-Min Kim; Seung Hyun Kim; Dae-Won Seo; Kwang-Woo Lee
Journal:  J Korean Med Sci       Date:  2013-08-28       Impact factor: 2.153

Review 9.  Patient positioning during minimally invasive surgery: what is current best practice?

Authors:  Jacqueline M Zillioux; Tracey L Krupski
Journal:  Robot Surg       Date:  2017-07-14

10.  Brachial Plexus Injury due to Central-line Insertion during Kypho-scoliosis Deformity Correction.

Authors:  Hitesh N Modi; Shakti A Goel; Arvind Sharma; Udit Patel
Journal:  J Orthop Case Rep       Date:  2021-07