Literature DB >> 8423931

99Tcm-methoxyisobutylisonitrile stress/rest SPECT in patients with constant complete left bundle branch block.

C Altehoefer1, J Vom Dahl, E Kleinhans, R Uebis, P Hanrath, U Buell.   

Abstract

Numerous studies have revealed frequent false positive septal findings of 201Tl stress imaging in patients with left bundle branch block (LBBB) even with angiographically excluded significant coronary artery disease (CAD). To scrutinize this phenomenon for stress/rest 99Tcm-methoxyisobutylisonitrile (MIBI) single photon emission computed tomography (SPECT) was used to review 22 patients with constant LBBB. The findings were reversible septal defect in one patient, partially reversible septal defect in one patient and irreversible septal defects in eight patients. In four patients 99Tcm-MIBI scans were entirely normal. Thus, 12/22 (55%) patients revealed normal septal 99Tcm-MIBI uptake. Both patients with a stress-induced septal defect revealed a significant left anterior descending artery stenosis on coronary angiography. These preliminary results suggest, that 99Tcm-MIBI might be more specific and accurate than 201Tl in the evaluation of CAD in patients with LBBB because of apparently rare or absent false positive septal findings.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8423931     DOI: 10.1097/00006231-199301000-00007

Source DB:  PubMed          Journal:  Nucl Med Commun        ISSN: 0143-3636            Impact factor:   1.690


  6 in total

1.  Clinical validation of technetium-99m MIBI-gated single-photon emission computed tomography (SPECT) for avoiding false positive results in patients with left bundle-branch block: comparison with stress-rest nongated SPECT.

Authors:  Hakan Demir; Güner Erbay; K Metin Kir; Kenan Omurlu; Fatma Berk; Cumali Aktolun
Journal:  Clin Cardiol       Date:  2003-04       Impact factor: 2.882

2.  Left bundle branch block and coronary artery disease: accuracy of dipyridamole thallium-201 single-photon emission computed tomography in patients with exercise anteroseptal perfusion defects.

Authors:  N E Lebtahi; J C Stauffer; A B Delaloye
Journal:  J Nucl Cardiol       Date:  1997 Jul-Aug       Impact factor: 5.952

3.  Sequential SPECT/CT imaging starting with stress SPECT in patients with left bundle branch block suspected for coronary artery disease.

Authors:  Elsemiek M Engbers; Jorik R Timmer; Mohamed Mouden; Siert Knollema; Pieter L Jager; Jan Paul Ottervanger
Journal:  Eur Radiol       Date:  2016-05-11       Impact factor: 5.315

4.  Usefulness of myocardial perfusion SPECT in patients with left bundle branch block and previous myocardial infarction.

Authors:  J Candell-Riera; G Oller-Martínez; O Pereztol-Valdés; J Castell-Conesa; S Aguadé-Bruix; M Soler-Peter; M Simó; C Santana-Boado; J Soler-Soler
Journal:  Heart       Date:  2003-09       Impact factor: 5.994

5.  Adenosine Stress Induced Left Bundle Branch Block During Technetium-99m Tetrofosmin Myocardial Perfusion Imaging.

Authors:  Mohan Roop Jayanthi; Arun Sasikumar; Arun Kumar Reddy Gorla; Ashwani Sood; Anish Bhattacharya; Bhagwant Rai Mittal
Journal:  World J Nucl Med       Date:  2017 Jan-Mar

Review 6.  Myocardial perfusion scintigraphy - interpretation of gated imaging. Part 2.

Authors:  Monika Z Czaja; Zbigniew Wygoda; Agata Duszańska; Dominik Szczerba; Jan Głowacki; Mariusz Gąsior; Jarosław P Wasilewski
Journal:  Kardiochir Torakochirurgia Pol       Date:  2018-03-28
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.