Severe fractures of the distal radius: effect of amount and duration of external fixator distraction on outcome.

F A Kaempffe1, D R Wheeler, C A Peimer, K S Hvisdak, J Ceravolo, J Senall.   

Abstract

Although severe intra-articular fractures of the distal radius are often treated with external fixation/distraction, little attention has been devoted to the amount and duration of fixator distraction required to maximize outcome. To determine these effects, we conducted a retrospective study of 26 patients whose primary treatment was external fixation/distraction. Patients were evaluated by chart review, questionnaire, x-ray films, and physical examination an average of 104 weeks after injury. The carpal height index was used to quantify distraction. Scores for pain, function, wrist motion, and grip strength and the total score were adversely affected in proportion to the increase in carpal height index by distraction. Outcome was adversely affected as the duration of distraction increased. Motion scores were affected most. Overall, patients recovered at least 75% of motion and grip strength, and 85% attained New York Orthopedic Hospital grades of good or excellent. These are the first data to show that there are potential adverse effects from increasing amounts of distraction and prolonged use of the external fixator.

Entities:  

Mesh:

Year:  1993        PMID: 8423314     DOI: 10.1016/0363-5023(93)90241-T

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  11 in total

1.  Outcome following distally locked volar plating for distal radius fractures with metadiaphyseal involvement.

Authors:  Kristofer S Matullo; David G Dennison
Journal:  Hand (N Y)       Date:  2015-06

2.  External fixation of intra-articular fracture of the distal radius in young and old adults.

Authors:  K Huch; M Hünerbein; P J Meeder
Journal:  Arch Orthop Trauma Surg       Date:  1996       Impact factor: 3.067

3.  Conformational changes in the carpus during finger trap distraction.

Authors:  Evan L Leventhal; Douglas C Moore; Edward Akelman; Scott W Wolfe; Joseph J Crisco
Journal:  J Hand Surg Am       Date:  2010-02       Impact factor: 2.230

4.  Volar long locking compression plate fixation for distal radius fractures with metaphyseal and diaphyseal extension.

Authors:  Sang Ki Lee; Dong Wook Seo; Kap Jung Kim; Dae Suk Yang; Won Sik Choy
Journal:  Eur J Orthop Surg Traumatol       Date:  2012-04-19

5.  Plate fixation of distal radius fracture and related complications.

Authors:  Laurent Obert; Francois Loisel; Sonia Huard; Séverin Rochet; Daniel Lepage; Gregoire Leclerc; Patrick Garbuio
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-10-02

6.  External fixation with or without supplementary intramedullary Kirschner wires in the treatment of distal radial fractures.

Authors:  Charles Lin; Jui-Sheng Sun; Sheng-Mou Hou
Journal:  Can J Surg       Date:  2004-12       Impact factor: 2.089

7.  A prospective comparison between Kapandji and percutaneous extra-focal fixation in extra articular distal radius fractures.

Authors:  Seyed Mehdi Mirhamidi; Farzad Merrikh Bayat
Journal:  Int J Clin Exp Med       Date:  2013-01-26

8.  No Higher Risk of CRPS After External Fixation of Distal Radial Fractures - Subgroup Analysis Under Randomised Vitamin C Prophylaxis.

Authors:  Paul E Zollinger; Robert W Kreis; Hub G van der Meulen; Maarten van der Elst; Roelf S Breederveld; Wim E Tuinebreijer
Journal:  Open Orthop J       Date:  2010-02-17

9.  The role of locking technology in the upper extremity.

Authors:  Siddharth B Joglekar; Asif M Ilyas
Journal:  J Hand Microsurg       Date:  2010-01-08

10.  Hybrid external fixation for neglected fractures of the distal radius: results after one year.

Authors:  Paweł Grala; Wojciech Zieliński
Journal:  J Orthop Traumatol       Date:  2008-09-19