A comparison of photographic and transparency-based methods for measuring wound surface area.

J W Griffin1, E A Tolley, R E Tooms, R A Reyes, J K Clifft.   

Abstract

BACKGROUND AND
PURPOSE: The purposes of this study were to compare test-retest reliability of measurements obtained by the use of a photographic method and those obtained by the use of a transparency method and to compare wound surface area (WSA) measurements obtained by these two methods.
SUBJECTS: Twenty inpatients (18 male, 2 female), aged 31 +/- 16 years (mean +/- SD), participated in the study.
METHODS: Tracings of ulcer borders generated by the photographic and transparency methods were digitized to obtain WSA measurements. To assess intrarater reliability for each method, 5 ulcers were measured on two occasions. The magnitude of WSA measurements obtained by the photographic and transparency methods was compared in 22 ulcers measured on one occasion and in 16 ulcers measured at 5-day intervals for 20 days.
RESULTS: Intraclass correlation coefficients (ICCs) were high (ICC = .99) for each method, indicating reliability of measurements. The WSA measurements did not differ between photographic and transparency methods, either at one occasion or over a 20-day period. CONCLUSION AND DISCUSSION: We concluded that the photographic and transparency methods, as applied in this study of ulcers, provided equivalently reliable measurements and that WSA measurements obtained by the two methods were equivalent. The transparency method was more economical than the photographic method in terms of time and equipment requirements.

Entities:  

Mesh:

Year:  1993        PMID: 8421717     DOI: 10.1093/ptj/73.2.117

Source DB:  PubMed          Journal:  Phys Ther        ISSN: 0031-9023


  9 in total

1.  Computer-assisted measurement of wound size associated with self-injurious behavior.

Authors:  David M Wilson; Brian A Iwata; Sarah E Bloom
Journal:  J Appl Behav Anal       Date:  2012

2.  Assessment of the Size of the Surgical Site in Minimally Invasive Hip Surgery.

Authors:  David Putzer; Matthias Haselbacher; Sebastian Klug; Michael Nogler
Journal:  Adv Wound Care (New Rochelle)       Date:  2014-06-01       Impact factor: 4.730

3.  Digital photography and transparency-based methods for measuring wound surface area.

Authors:  Amul Bhedi; Atul K Saxena; Ravi Gadani; Ritesh Patel
Journal:  Indian J Surg       Date:  2012-03-28       Impact factor: 0.656

4.  Wound healing monitoring using near infrared fluorescent fibrinogen.

Authors:  Chia-Pin Pan; Yihui Shi; Khalid Amin; Charles S Greenberg; Zishan Haroon; Gregory W Faris
Journal:  Biomed Opt Express       Date:  2010-07-27       Impact factor: 3.732

5.  A comparison of wound area measurement techniques: visitrak versus photography.

Authors:  Angela Christine Chang; Bronwyn Dearman; John Edward Greenwood
Journal:  Eplasty       Date:  2011-04-18

6.  A cost-effective transparency-based digital imaging for efficient and accurate wound area measurement.

Authors:  Pei-Nan Li; Hong Li; Mo-Li Wu; Shou-Yu Wang; Qing-You Kong; Zhen Zhang; Yuan Sun; Jia Liu; De-Cheng Lv
Journal:  PLoS One       Date:  2012-05-30       Impact factor: 3.240

7.  The evaluation of off-loading using a new removable oRTHOsis in DIABetic foot (ORTHODIAB) randomized controlled trial: study design and rational.

Authors:  Kamel Mohammedi; Louis Potier; Maud François; Dured Dardari; Marilyne Feron; Estelle Nobecourt-Dupuy; Manuel Dolz; Roxane Ducloux; Abdelkader Chibani; Dominique-François Eveno; Teresa Crea Avila; Ariane Sultan; Laurence Baillet-Blanco; Vincent Rigalleau; Gilberto Velho; Florence Tubach; Ronan Roussel; Jean-Claude Dupré; Dominique Malgrange; Michel Marre
Journal:  J Foot Ankle Res       Date:  2016-08-22       Impact factor: 2.303

8.  Comparison of standardized clinical evaluation of wounds using ruler length by width and Scout length by width measure and Scout perimeter trace.

Authors:  Diane Langemo; James Spahn; Thomas Spahn; V Chowdry Pinnamaneni
Journal:  Adv Skin Wound Care       Date:  2015-03       Impact factor: 2.347

9.  Comprehensive measurement of UVB-induced non-melanoma skin cancer burden in mice using photographic images as a substitute for the caliper method.

Authors:  Marc Bazin; Nupur K Purohit; Girish M Shah
Journal:  PLoS One       Date:  2017-02-10       Impact factor: 3.240