Characterization of a multi-leaf collimator system.

J M Galvin1, A R Smith, B Lally.   

Abstract

Commissioning measurements for a multi-leaf collimator installed on a dual energy accelerator with 6 and 15 MV photons are described. Detailed dosimetric characterization of the multi-leaf collimator is a requirement for modeling the collimator with treatment planning software. Measurements include a determination of the penumbra width, leaf transmission, between-leaf leakage, and localization of the leaf ends and sides. Standard radiographic film was used for the penumbra measurements, and separate experiments using radiochromic film and thermoluminescent dosimeters were performed to verify that distortions of the dose distribution at an edge due to changing energy sensitivity of silver bromide film are negligible. Films were analyzed with a scanning laser densitometer with a 210 micron spot. Little change in the penumbra edge distribution was noted for different positions of a leaf in the field. Experiments localizing the physical end of the leaves showed less than 1 mm deviation from the 50% decrement line. This small difference is attributed to the shaped end on the leaves. One side of a single leaf corresponded to the 50% decrement line, but the opposite face was aligned with a lower value. This difference is due to the tongue and groove used to decrease between-leaf leakage. For both energies, approximately 2% of photons incident on the multi-leaf collimator are transmitted and an additional 0.5% leakage occurs between the leaves. Alignment of the leaves to form a straight edge results in a penumbra profile which compares favorably with the standard technique of using alloy blocks. When the edge is stepped, the isodose lines follow the leaf pattern and the boundary is poorly defined compared to divergent blocks.

Entities:  

Mesh:

Year:  1993        PMID: 8420867     DOI: 10.1016/0360-3016(93)90339-w

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  16 in total

1.  Clinical use of a simulation-multileaf collimator.

Authors:  M Marx; P Vacha; B Riis; T Feyerabend; E Richter
Journal:  Strahlenther Onkol       Date:  1998-07       Impact factor: 3.621

Review 2.  Current status of IMRT in head and neck cancer.

Authors:  Jaime Gomez-Millan; Jesús Romero Fernández; Jose Antonio Medina Carmona
Journal:  Rep Pract Oncol Radiother       Date:  2013-10-20

3.  Dosimetry and evaluating the effect of treatment parameters on the leakage of multi leaf collimators in ONCOR linear accelerators.

Authors:  Keyvan Jabbari; Muhaddeseh Akbari; Mohamad Bagher Tavakoli; Alireza Amouheidari
Journal:  Adv Biomed Res       Date:  2016-12-27

4.  Stereotactic IMRT for prostate cancer: dosimetric impact of multileaf collimator leaf width in the treatment of prostate cancer with IMRT.

Authors:  L Wang; B Movsas; R Jacob; E Fourkal; L Chen; R Price; S Feigenberg; A Konski; A Pollack; C Ma
Journal:  J Appl Clin Med Phys       Date:  2004-04-01       Impact factor: 2.102

5.  A light field-based method to adjust rounded leaf end MLC position for split shape dose calculation correction in a radiation therapy treatment planning system.

Authors:  Jia-Ming Wu; Tsair-Fwu Lee; Chung-Ming Kuo; Ching-Jiang Chen; Shyh-An Yeh
Journal:  J Appl Clin Med Phys       Date:  2012-11-08       Impact factor: 2.102

6.  Virtual micro MLC commissioning.

Authors:  Laura Drever; Peter Dickof
Journal:  J Appl Clin Med Phys       Date:  2005-05-19       Impact factor: 2.102

7.  Physical and dosimetric characteristic of high-definition multileaf collimator (HDMLC) for SRS and IMRT.

Authors:  Dayananda Shamurailatpam Sharma; Prabhakar M Dongre; Vaibav Mhatre; Malhotra Heigrujam
Journal:  J Appl Clin Med Phys       Date:  2011-04-14       Impact factor: 2.102

8.  Dosimetric evaluation of 120-leaf multileaf collimator in a Varian linear accelerator with 6-MV and 18-MV photon beams.

Authors:  R Mohan; K Jayesh; R C Joshi; Maha Al-Idrisi; P Narayanamurthy; Saroj Kumar Das Majumdar
Journal:  J Med Phys       Date:  2008-07

9.  A light-field-based method to adjust on-axis rounded leaf end MLC position to predict off-axis MLC penumbra region dosimetric performance in a radiation therapy planning system.

Authors:  Jia-Ming Wu; Tsair-Fwu Lee; Shyh-An Yeh; Kuan-Yin Hsiao; Hsin-Hsiung Chen; Pei-Ju Chao; Yi-Ting Chen
Journal:  Biomed Res Int       Date:  2013-10-24       Impact factor: 3.411

10.  Optimization of the rounded leaf offset table in modeling the multileaf collimator leaf edge in a commercial treatment planning system.

Authors:  John R Rice
Journal:  J Appl Clin Med Phys       Date:  2014-11-08       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.