Literature DB >> 8414428

The rationale for cementless revision total hip replacement with contemporary technology.

R S Gorab1, B M Covino, L S Borden.   

Abstract

Undoubtedly, the number of revisions for failed cemented total hip arthroplasties will increase over time based on current survival statistics. Although contemporary cementing techniques may improve the outcome of some procedures, long-term results of cemented revisions are less than ideal. Poor bone quality with cortical deficiencies and endosteal sclerosis make long-term stability and implant survival less likely with cemented techniques. In the very elderly patient requiring revision, PMMA may provide a simpler option with an adequate short-term result. Using uncemented techniques, the complications associated with the inherent properties of cement can be avoided. Bone grafting is a viable option, with the hope that long-term implant stability can be achieved by biological ingrowth into porous surfaces. Reconstitution of previously attenuated cortical bone is seen after bone grafting in association with a noncemented femoral or acetabular implant, although ingrowth into porous-coated surfaces via allograft bone is unlikely. In general, short- and mid-term results with respect to clinical performance are good or excellent in at least 90% of the cases evaluated. With the increased application of uncemented components to revision situations, attention may shift from "cement" disease to "polyethylene" disease. Although not the focus of this article, recent literature with respect to primary uncemented hip and knee arthroplasty supports this contention. We believe that proximal canal fill and biologic ingrowth can provide implant stability, avoid proximal stress shielding of the femur, and improve long-term implant survival and clinical success in the revision situation.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8414428

Source DB:  PubMed          Journal:  Orthop Clin North Am        ISSN: 0030-5898            Impact factor:   2.472


  3 in total

1.  High medium-term survival of Zweymüller SLR-plus stem used in femoral revision.

Authors:  Panagiotis Korovessis; Thomas Repantis
Journal:  Clin Orthop Relat Res       Date:  2009-03-03       Impact factor: 4.176

2.  Results of Wagner SL revision stem with impaction bone grafting in revision total hip arthroplasty.

Authors:  Somesh P Singh; Haresh P Bhalodiya
Journal:  Indian J Orthop       Date:  2013-07       Impact factor: 1.251

3.  Downsizing in total hip arthroplasty. A short stem as a revision implant.

Authors:  Marcel Coutandin; Yama Afghanyar; Philipp Rehbein; Jens Dargel; Philipp Drees; Karl Philipp Kutzner
Journal:  Orthopade       Date:  2021-09-28       Impact factor: 1.087

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.