Literature DB >> 8413025

Computer-assisted positioning of radiotherapy patients using implanted radiopaque fiducials.

K P Gall1, L J Verhey, M Wagner.   

Abstract

For certain external beam radiotherapy procedures, precise alignment of patients with the treatment beam is essential for good treatment outcome. A method has been developed for quickly achieving precise patient alignment with the aid of stereoscopically located fiducial markers. The alignment algorithm is developed from standard rigid body mechanics using closed form solutions, obviating the need for iterative fitting methods. The technique is implemented with a digitizing tablet and plane film radiographs. The accuracy of alignment with this method in phantom studies is better than 1 mm and 1 deg relative to CT data. The repeatability of positioning is 0.5 mm (standard deviation) and 0.36 deg (standard deviation).

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8413025     DOI: 10.1118/1.596969

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  11 in total

1.  Three-dimensional point localisation in low-dose X-ray images using stereo-photogrammetry.

Authors:  T S Douglas; C L Vaughan; S M Wynne
Journal:  Med Biol Eng Comput       Date:  2004-01       Impact factor: 2.602

Review 2.  Proton therapy for tumors of the skull base.

Authors:  J E Munzenrider; N J Liebsch
Journal:  Strahlenther Onkol       Date:  1999-06       Impact factor: 3.621

3.  The influence of patient positioning uncertainties in proton radiotherapy on proton range and dose distributions.

Authors:  Jakob Liebl; Harald Paganetti; Mingyao Zhu; Brian A Winey
Journal:  Med Phys       Date:  2014-09       Impact factor: 4.071

Review 4.  The physics of proton therapy.

Authors:  Wayne D Newhauser; Rui Zhang
Journal:  Phys Med Biol       Date:  2015-03-24       Impact factor: 3.609

5.  Case report. Fractionated Helical Tomotherapy as an alternative to radiosurgery in patients unwilling to undergo additional radiosurgery for recurrent brain metastases.

Authors:  P Sanghera; A W Lightstone; D E Hyde; P Davey
Journal:  Br J Radiol       Date:  2010-02       Impact factor: 3.039

6.  Evaluation of Image Enhancement Method on Target Registration Using Cone Beam CT in Radiation Therapy.

Authors:  Hui Yan; Ren Lei; Jackie Wu; Fu Di; Fang-Fang Yin
Journal:  Clin Med Oncol       Date:  2008-03-28

7.  Evaluation of gold fiducial marker manual localisation for magnetic resonance-only prostate radiotherapy.

Authors:  Matteo Maspero; Peter R Seevinck; Nicole J W Willems; Gonda G Sikkes; Geja J de Kogel; Hans C J de Boer; Jochem R N van der Voort van Zyp; Cornelis A T van den Berg
Journal:  Radiat Oncol       Date:  2018-06-05       Impact factor: 3.481

8.  Dose perturbations from implanted helical gold markers in proton therapy of prostate cancer.

Authors:  Annelise Giebeler; Jonas Fontenot; Peter Balter; George Ciangaru; Ronald Zhu; Wayne Newhauser
Journal:  J Appl Clin Med Phys       Date:  2009-01-27       Impact factor: 2.102

9.  Migration of implanted markers for image-guided lung tumor stereotactic ablative radiotherapy.

Authors:  Julian C Hong; Neville C W Eclov; Yao Yu; Aarti K Rao; Sonja Dieterich; Quynh-Thu Le; Maximilian Diehn; Daniel Y Sze; Billy W Loo; Nishita Kothary; Peter G Maxim
Journal:  J Appl Clin Med Phys       Date:  2013-03-04       Impact factor: 2.102

10.  Determination of optimal fiducial marker across image-guided radiation therapy (IGRT) modalities: visibility and artifact analysis of gold, carbon, and polymer fiducial markers.

Authors:  Lydia L Handsfield; Ning J Yue; Jinghao Zhou; Ting Chen; Sharad Goyal
Journal:  J Appl Clin Med Phys       Date:  2012-09-06       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.