Automated determination of patient setup errors in radiation therapy using spherical radio-opaque markers.

K L Lam1, R K Ten Haken, D L McShan, A F Thornton.   

Abstract

Patient positioning accuracy can be quantified by the three-dimensional (3-D) translations and rotations required to transform the patient back to the desired position. Results of the current study show that the translations and rotations could be obtained from two projection images obtained radiographically on a linear accelerator when spherical radio-opaque markers were implanted inside or affixed to the surface of a skull phantom. In this study, film used to record the images were converted into digital gray scale images using a laser film digitizer. The marker images were located automatically by the computer using image processing techniques. By combining information from both projections, the 3-D locations of the markers were determined to submillimeter precision. Pairs of films were also analyzed for the phantom displaced from its original location by known amounts. The accuracy of the computed translations and rotations required for realignment of the phantom were found to be better than 1 mm and 0.3 degrees, respectively; comparable to the accuracy of the readout system of the equipment used. The general methodology could be coupled with an electronic portal imaging device for use in computer aided or automated correction of patient position in radiotherapy.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8413024     DOI: 10.1118/1.596968

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  Automated target tracking in kilovoltage images using dynamic templates of fiducial marker clusters.

Authors:  Warren G Campbell; Moyed Miften; Bernard L Jones
Journal:  Med Phys       Date:  2017-02       Impact factor: 4.071

2.  Accuracy and reproducibility of tumor positioning during prolonged and multi-modality animal imaging studies.

Authors:  Mutian Zhang; Minming Huang; Carl Le; Pat B Zanzonico; Filip Claus; Katherine S Kolbert; Kyle Martin; C Clifton Ling; Jason A Koutcher; John L Humm
Journal:  Phys Med Biol       Date:  2008-09-30       Impact factor: 3.609

3.  Prostate immobilization using a rectal balloon.

Authors:  John E McGary; Bin S Teh; E Brian Butler; Walter Grant
Journal:  J Appl Clin Med Phys       Date:  2002       Impact factor: 2.102

4.  A clinical evaluation of setup errors for a prostate immobilization system.

Authors:  J E McGary; W Grant
Journal:  J Appl Clin Med Phys       Date:  2000       Impact factor: 2.102

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.