Literature DB >> 8412372

Ocular microtremor measurement system: design and performance.

N F Sheahan1, D Coakley, F Hegarty, C Bolger, J Malone.   

Abstract

The frequency of ocular microtremor (OMT) is related to the functional status of the brain stem, and thus OMT may be useful in the diagnosis and management of brain stem disorders. The paper discusses the design of an OMT measurement system and reports quantitative specifications for three portable systems. All systems use a piezo-electric element as the transducer, which measures the displacement of the sclera during eye rotations. The systems differ in the manner in which the signal is recorded. All systems can detect eye movements corresponding to displacements of the sclera ranging from 12 to over 3000 nm. The frequency responses of all systems are flat (< 2 dB deviation from peak response) between 20 and 150 Hz. The phase response shows deviations (< pi) at the extremes of this range, but qualitative comparison of input and measured signals demonstrates that phase distortion is not excessive. Thus all systems are acceptable for clinical studies involving OMT.

Entities:  

Mesh:

Year:  1993        PMID: 8412372     DOI: 10.1007/bf02458038

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  18 in total

1.  Motions of the retinal image during fixation.

Authors:  L A RIGGS; J C ARMINGTON; F RATLIFF
Journal:  J Opt Soc Am       Date:  1954-04

2.  Visual acuity and the normal tremor of the eyes.

Authors:  L A RIGGS; F RATLIFF
Journal:  Science       Date:  1951-07-06       Impact factor: 47.728

3.  Three electronic methods for recording ocular tremor.

Authors:  H Bengi; J G Thomas
Journal:  Med Biol Eng       Date:  1968-03

4.  Precise non-contacting measurement of eye movements using the corneal reflex.

Authors:  M Eizenman; R C Frecker; P E Hallett
Journal:  Vision Res       Date:  1984       Impact factor: 1.886

5.  [Ocular microtremor--an indicator of the functional status of the brain stem].

Authors:  M Michalik
Journal:  Psychiatr Neurol Med Psychol Beih       Date:  1983

6.  Power spectra for ocular drift and tremor.

Authors:  M Eizenman; P E Hallett; R C Frecker
Journal:  Vision Res       Date:  1985       Impact factor: 1.886

7.  An investigation of the correlation between abnormal patterns of ocular microtremor and an abnormal pupil reflex in neurological patients.

Authors:  L Y Abakumova; A R Shakhnovich; J G Thomas
Journal:  J Neurol Sci       Date:  1975-12       Impact factor: 3.181

8.  [Spectral analyses in ocular microtremor in disorders of brain stem function].

Authors:  M Michalik
Journal:  EEG EMG Z Elektroenzephalogr Elektromyogr Verwandte Geb       Date:  1987-03

9.  The ocular microtremor record as a potential procedure for establishing brain death.

Authors:  D Coakley; J G Thomas
Journal:  J Neurol Sci       Date:  1977-03       Impact factor: 3.181

10.  Micro-tremor of the eyes of comatose patients.

Authors:  A R Shakhnovich; J G Thomas
Journal:  Electroencephalogr Clin Neurophysiol       Date:  1977-01
View more
  2 in total

1.  Simultaneous recordings of ocular microtremor and microsaccades with a piezoelectric sensor and a video-oculography system.

Authors:  Michael B McCamy; Niamh Collins; Jorge Otero-Millan; Mohammed Al-Kalbani; Stephen L Macknik; Davis Coakley; Xoana G Troncoso; Gerard Boyle; Vinodh Narayanan; Thomas R Wolf; Susana Martinez-Conde
Journal:  PeerJ       Date:  2013-02-12       Impact factor: 2.984

2.  A Bayesian computational model for online character recognition and disability assessment during cursive eye writing.

Authors:  Julien Diard; Vincent Rynik; Jean Lorenceau
Journal:  Front Psychol       Date:  2013-11-11
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.