Effect of an ultrasonic device on temperatures generated in bone and on bone-cement structure.

A T Brooks1, C L Nelson, C L Stewart, R A Skinner, M L Siems.   

Abstract

Cement removal during revision arthroplasty can be a tedious, time-consuming process. The usual methods of removing cement include high-speed drills, chisels, saws and reamers, which are often associated with fracture and/or perforation of the femoral shaft. Ultrasound has been used in dentistry to remove plaque and in ophthalmology to remove cataracts and is now applied to cement removal in orthopaedic surgery. There is little data available on the effect of ultrasound on temperatures generated in bone and on its effects on the structure of bone-cement. A cement mantle was constructed in the intramedullary canal in each of six 10 cm lengths of human cadaver femora. A temperature probe was then inserted into predrilled holes and temperatures generated by the ultrasonic device were recorded under a variety of conditions. In addition, a cement cylinder was microscopically evaluated after an ultrasonic tool had been inserted. Temperatures generated by the ultrasonic tool in cadaver bone were no higher than previously reported temperatures of 140 degrees C generated by high-speed drills. Furthermore, temperatures at the bone-cement interface never exceeded 60 degrees C when saline irrigation was used in conjunction with the ultrasonic tools, and were below 40 degrees C 1 minute after deactivation of the device. Microscopic examination shows that ultrasound produced local changes in the structure of bone-cement converting it from a microscopically spherical interlocked material to one that appears homogeneous and granular.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8409994     DOI: 10.1016/s0883-5403(06)80041-0

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  5 in total

1.  Thermomechanical method for cement extraction in revision arthroplasty.

Authors:  M Ghanem; A Koenig; F Dehn; C-E Heyde; C Josten
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-03-18

2.  Ultrasonic bone scalpel: utility in cervical corpectomy. A technical note.

Authors:  Bharat R Dave; Devanand Degulmadi; Shreekant Dahibhate; Ajay Krishnan; Denish Patel
Journal:  Eur Spine J       Date:  2018-03-14       Impact factor: 3.134

3.  Management of Giant Calcified Thoracic Disks and Description of the Trench Vertebrectomy Technique.

Authors:  Rafid Al-Mahfoudh; Paul S Mitchell; Martin Wilby; Daniel Crooks; Chris Barrett; Robin Pillay; Tim Pigott
Journal:  Global Spine J       Date:  2015-12-19

4.  Technical Aspects on the Use of Ultrasonic Bone Shaver in Spine Surgery: Experience in 307 Patients.

Authors:  Derya Burcu Hazer; Barış Yaşar; Hans-Eric Rosberg; Aytaç Akbaş
Journal:  Biomed Res Int       Date:  2016-04-18       Impact factor: 3.411

5.  Combination of modified mixing technique and low frequency ultrasound to control the elution profile of vancomycin-loaded acrylic bone cement.

Authors:  A Wendling; D Mar; N Wischmeier; D Anderson; T McIff
Journal:  Bone Joint Res       Date:  2016-02       Impact factor: 5.853

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.